Before you start...
Before you start...
Confirm you have all the correct parts and tool required.
Box contents
1x
3x
Plumbing Specification
Plumbing Specification
This product is rated at IP45 and suitable to be installed in Zone 1, 2 or Zone 3 of a
shower room only if these instructions are fully complied with.
The unit must be located away from the direct line of water jets.
Note: Zone 1 lies above zone 0 and upto 2250mm (88in) vertically above a shower tray
or wet floor area.
The perimeter of zone 1 of a wet floor is within a 1.2 metres (47in) radius of the
shower head position. Zone 2 is the area 600mm beyond Zone 1.
2x
22mm
2x
22mm
FOR GUIDANCE ONLY- PLEASE REFER TO BS7671 FOR FURTHER DETAILS