When the portion is the size you want, close the handle and
The outer tube is actually a valve. Rotating it from hole to hole
pull the cup or cone straight down to add a peak.
on the outer tube varies the size of the hole and the amount of
Typical portion sizes are: SMALL = 3 OUNCE SERVING
MEDIUM
=
5 OUNCE SERVING
LARGE = 7 OUNCE SERVING
mix that flows into the freezing cylinder. The size of the alr
inlet, at the top of the tube, does not change so the amount of
air that enters the freezing cylinder is constant.
You can vary the overrun (yield) by letting more or less mix
enter the freezing cyl~nder by manually regulating the valve.
You must align the mix inlet holes on both the inner and outer
tubes or no mix will enter the cylinder. You can see this hole at
the top of both tubes. See illustration below.
Figure 1 2
Gravity Feed Tube Adjustment Settings
The plunger/splash guard keeps the mix from splashing on the
mix tank cover and serves as a device to eliminate potent~al
clogging inside the tubes
You may find it necessary to.adjust the position of the outer
Gravity Feed Valve
-
HOW to
tube in order to regulate the amount of mix entering the
Operate and Make Adjustments
freezing cylinder after start-up. Actually, sales conditions will
dictate the proper adjustment.
The Gravity Feed Valve consists of two tubes. one slid~rlg inside
If more production is required, increase the opening by rotating
the other, and a plungerlsplash guard.
the outer tube to a laraer hole, and converselv when business
-
The inner tube blends the flow of air and mix into the freezing
is slow, rotate to a smaller hole on the outer tube, reducing the
.,
cylinder. Air enters through the top of the tube and the mlx.
opening. Naturally, when the mix runs low in the mix tank, you
through a round hole at the base. See illustration below
will open the slot more and eventually take the feed tube out
completely to use the last of mix in the mix tank.
Energy Conservation
During long idle periods. it is recammended the outer sleeve of
the gravity feed tube be rotated to the position which closes
the mix intake hole completely.
IMPORTANT. Remember to rotate the outer tube to the appro-
priate opening Sefore switching to the AUTO mode.
For further Operational or Technical Data, please refer to the
"Operation and Service Manual" or contact your authorized