coldline ICE550M-HA Benutzerhandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Eiswürfelbereiter coldline ICE550M-HA herunter. coldline ICE550M-HA 13 Seiten.
The fault code and its comments are displayed as follows:
Code
Comments
E01
Sliding board fails
Overtime of ice
E03
making
E04
High temperature
E05
Water shortage
E06
High pressure
Parameters on the Control Panel
Please kindly note: "Ice Thickness +" (here after we say "+") is the first
buttonto press if you wanna restore the original parameters; However, "Ice
Thickness -" (here after we say "-") is the first button to press if you want to
adjust the ice thickness.
Restore The Original Parameters
Generally the original parameters is not allowed to be changed, but if customers
change the numbers carelessly, please process the following steps to solve it:
Firstly check the display numbers as per our correct original numbers , for example
model SK-500P: "220, 308 ,405, 501, 640, 708, 820, 901". If it is not same, we
needto adjust the display numbers until it is same with the correct.
Here we take SK-500P as example. Adjustment operation: press"+" button, if the
first number is 220, then press "+", come to display number 308, if it is not 308, now
you need to press "-" to check whether it is 308, if it display the correct number 308,
then we press "+" again" to come to 4-serial number, the next steps are same, just
repeat ituntil all numbers are correct.
NOTE: Next time do not press"+" directly, because this may
change the originalparameters.
、
Machine action
Protective
shutdown
Protective
shutdown
Protective
shutdown
Protective
shutdown
Protective
Original Parameters Display
USRESTAURANT® RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE
Condensation
E07
sensor open circuit
Condensation
E08
sensor short circuit
Water temp.
E09
sensor open circuit
Water temp.
E10
sensor short circuit
"+-" buttons
shutdown
Not stop
Not stop
Not stop
Not stop
7