Expand Serial Command Functional Specification
8.11.9. CF_P-MANE Command
Command
"CF_P-MANE_%1" [CR]
" O F F " - - - - - - - - - - - - - - - Set Power Management to Off
%1
" R E A D Y " - - - - - - - - - - - Set Power Management to Ready
" S H U T D O W N " - - - - Set Power Management to Shut Down
Set / Cancel Power management. (Only valid when it is in the usual Power On
status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable
8.11.10. CF_P-MANETIME Command
Command
"CF_P-MANETIME_%1" [CR]
"01" – "30" --------- Directly set the time by the minute
%1
"UP" ----------------- Set the time 1 minute longer
"DN" ----------------- Set the time 1 minute shorter
Set Power Management time. (Only valid when it is in the usual Power On
status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable
8.11.11 CF_FANSPEED Command
Command
"CF_FANSPEED_%1" [CR]
"MAX" --------- Select Maximum speed
%1
"NOR" ---------- Select Normal speed
Change Fan Control speed. (Only valid when it is in the usual Power On status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable
8.11.12. CF_KEYDIS Command
Command
"CF_KEYDIS_%1" [CR]
"NONE" ---------- RC and KEY are available
%1
"RC" --------------- Key lock RC
"KEY" ------------- Key lock Unit
Details
Set Key lock the RC / KEY. (Only valid when it is in the usual Power On status)
Acceptable
Response
Unacceptable
8.11.13. CF_TERMINAL Command
Command
"CF_TERMINAL_%1" [CR]
"COMPUTER" -------- Set Input mode
%1
"MONITOR" ----------- Set Monitor Output
Set Terminal. (Only valid when it is in the usual Power On status)
Details
In this model, Terminal is COMPTUER2.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
Page 25 of 41