Baumer Clever Level LBFH Betriebsanleitung - Seite 10

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Zubehör Baumer Clever Level LBFH herunter. Baumer Clever Level LBFH 34 Seiten. Point level detection – hygienic/industrial

Baumer Clever Level LBFH Betriebsanleitung
CleverLevel
Point level detection – hygienic/industrial
11. Disposal
Do not dispose of in household
f
„
waste.
Separate materials and dispose
f
„
of in compliance with nationally
applicable regulations.
12. Accessories
For adapter and other accessories see www.baumer.com.

13. Technical data

Environmental conditions
Operating temperature
range
Storage temperature range
Ambient humidity
Protection class
Oscillations (sinusoidal)
(EN 60068-2-6)
Power supply
Voltage supply range
Reverse polarity protec-
tion
Current consumption
(without load)
Acceleration time
10 / 33
Level measurement
®
LBFH/I
-40 ... -85 °C
„
„
-40 ... -85 °C
„
„
< 98 % RH,
„
„
condensing
IP67
„
„
IP69K (with
„
„
appropriate cable)
1.6 mm p-p
„
„
(2 ... 25 Hz),
4 g (25 ...100 Hz),
1 octave / min.
8 ... 36 V DC
„
„
yes
„
„
25 mA type.,
„
„
50 mA max.
< 3 s
„
„
Operating Instructions
Features
Repeatability
„
Hysteresis
„
Response time
„
Damping
„
Output signal
Output type
„
„
„
Current load
„
Short circuit protec-
„
tion
Voltage drop
„
„
Leakage current
„
Switching logic
„
„
± 1 mm
„
± 1 mm
„
0.02 s type.
„
0.1 ... 10.0 s (adjustable)
„
PNP
„
NPN
„
Digital (push-pull)
„
100 mA max.
„
yes
„
PNP: (+Vs -0.5 V) ± 0.2 V,
„
Rload = 10 kΩ
NPN: (+0.5 V) ± 0.5 V,
„
Rload = 10 kΩ
± 100 μA max.
„
Normally open (NO), active
„
low
Normally closed (NC), high
„
enabled
www.baumer.com