Baumer Clever Level LBFH Manuale di istruzioni per l'uso - Pagina 10
Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Accessories Baumer Clever Level LBFH. Baumer Clever Level LBFH 34. Point level detection – hygienic/industrial
CleverLevel
Point level detection – hygienic/industrial
11. Disposal
Do not dispose of in household
f
waste.
Separate materials and dispose
f
of in compliance with nationally
applicable regulations.
12. Accessories
For adapter and other accessories see www.baumer.com.
13. Technical data
Environmental conditions
Operating temperature
range
Storage temperature range
Ambient humidity
Protection class
Oscillations (sinusoidal)
(EN 60068-2-6)
Power supply
Voltage supply range
Reverse polarity protec-
tion
Current consumption
(without load)
Acceleration time
10 / 33
Level measurement
®
LBFH/I
-40 ... -85 °C
-40 ... -85 °C
< 98 % RH,
condensing
IP67
IP69K (with
appropriate cable)
1.6 mm p-p
(2 ... 25 Hz),
4 g (25 ...100 Hz),
1 octave / min.
8 ... 36 V DC
yes
25 mA type.,
50 mA max.
< 3 s
Operating Instructions
Features
Repeatability
Hysteresis
Response time
Damping
Output signal
Output type
Current load
Short circuit protec-
tion
Voltage drop
Leakage current
Switching logic
± 1 mm
± 1 mm
0.02 s type.
0.1 ... 10.0 s (adjustable)
PNP
NPN
Digital (push-pull)
100 mA max.
yes
PNP: (+Vs -0.5 V) ± 0.2 V,
Rload = 10 kΩ
NPN: (+0.5 V) ± 0.5 V,
Rload = 10 kΩ
± 100 μA max.
Normally open (NO), active
low
Normally closed (NC), high
enabled
www.baumer.com