Baumer DENEX Edge Detector II Benutzerhandbuch - Seite 9

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Zubehör Baumer DENEX Edge Detector II herunter. Baumer DENEX Edge Detector II 20 Seiten.

Baumer DENEX Edge Detector II Benutzerhandbuch
4.2

DIP-Switch Settings

An 8-pole DIP-switch can be reached via the lid on top of the sensor. Unscrewing the
screw opens the lid.
The software functions can be controlled via the DIP switches.
DIP-Switch positions
= OFF
= ON
DIP-switches 1-4 are reserved for factory.
DIP-switches 5-8 are for selecting operation mode
All in OFF-position is the default setting.
DIP-Switches
5 6 7 8
Mode 0 =
Default
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Mode 8
Mode 9
Mode 10
Mode 11
Laser power save mode is activated in all Counting/newspaper modes.
This means the laser power will be reduced to 50% after a 60 seconds gap.
User Manual DENEX Edge Detector II
Version 2013-02, V1.6
Commercial products: For timing applications, Blocking 15%, Output 5 ms
Counting application: Blocking time 30%, Output 5 ms
Timing application: Blocking time 15%, Output: 20 ms
Counting mode: Blocking time 15%,Otput: 20 ms
Newspapers, Blocking time 30%, Output: 20 ms
Edge detecting: Blocking time 15%, Output: 5 ms
Edge detecting: Blocking time 15%, Output: 20 ms
Cut edge first mode: Blocking time 46 %, Output 20 ms
Counting mode: Fixed blocking time = 7 ms, Output 5 ms.
Commercial: No Blocking, Output 5 ms
reserved
reserved
www.baumer.com
9/20
Baumer Electric AG
Frauenfeld, Switzerland