4.2
DIP-Switch Settings
An 8-pole DIP-switch can be reached via the lid on top of the sensor. Unscrewing the
screw opens the lid.
The software functions can be controlled via the DIP switches.
DIP-Switch positions
= OFF
= ON
DIP-switches 1-4 are reserved for factory.
DIP-switches 5-8 are for selecting operation mode
All in OFF-position is the default setting.
DIP-Switches
5 6 7 8
Mode 0 =
Default
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Mode 8
Mode 9
Mode 10
Mode 11
Laser power save mode is activated in all Counting/newspaper modes.
This means the laser power will be reduced to 50% after a 60 seconds gap.
User Manual DENEX Edge Detector II
Version 2013-02, V1.6
Commercial products: For timing applications, Blocking 15%, Output 5 ms
Counting application: Blocking time 30%, Output 5 ms
Timing application: Blocking time 15%, Output: 20 ms
Counting mode: Blocking time 15%,Otput: 20 ms
Newspapers, Blocking time 30%, Output: 20 ms
Edge detecting: Blocking time 15%, Output: 5 ms
Edge detecting: Blocking time 15%, Output: 20 ms
Cut edge first mode: Blocking time 46 %, Output 20 ms
Counting mode: Fixed blocking time = 7 ms, Output 5 ms.
Commercial: No Blocking, Output 5 ms
reserved
reserved