3.2.5.8 Store Parameters
Parameters can be saved with ASCII-command "save" in parameter 0x1010, subindex 1 with a specific key
(similar to CANopen Store command). A store command is important for all parameters which are not saved
at access (i.e. Digital Filter Cutoff Frequency)
Example:
COBID (example)
Direction
0x18EFF753
write to device
0x18EF53F7
received from device
3.2.5.9 Restore default
ASCII command "load" in parameter 0x1011, subindex 1 will restore the device default configuration.
Example:
COBID (example)
Direction
0x18EFF753
write to device
0x18EF53F7
received from device

Supported features

3.2.6
3.2.6.1 Address Claiming
Two devices with the same address in the same bus network will have the address claiming function
executed, meaning the new address is being assigned to the device of higher priority while the second
device is being assigned a higher address.
Baumer_GIM500R_SAEJ1939_MA_EN.docx
03.19
RAW-Data
0x 22 10 10 01 73 61 76 65
0x 60 10 10 01 00 00 00 00
RAW-Data
0x 22 11 10 01 6C 6F 61 64
0x 60 11 10 01 00 00 00 00
12/13