Baumer OM30 Betriebshandbuch - Seite 28
Blättern Sie online oder laden Sie pdf Betriebshandbuch für Messgeräte Baumer OM30 herunter. Baumer OM30 48 Seiten. Laser distance sensors
8
|
Functions
Processing of invalid measured values – example 2
Parameters:
n
▪ Type of processing of invalid measured values: min. output point
▪ Time period (Hold Time): 1000 ms
Interpretation: After expiration of the time period, the placeholder for an invalid value is out-
n
put at the digital output. For the analog output, the type of processing of invalid measured
values applies and the electrical power drops to 4 mA.
mm
250
50
Ill. 9: Processing of invalid measured values – example 2
IO-Link parameter: Processing of invalid measured values
Parameter name
AnalogSetting.Value after
Dropout
Process Value Disruption
Filter.Hold Time
28
Digital output
2147483644
1
2
3
4
5
Hold Time
Values
Last valid,
near, far
-
Operating Manual
mA
20
4
s
Signal quality
Description
Type of processing of invalid measured val-
n
ues:
▪ Last valid: Last valid measured value
▪ near: min. output point
▪ far: max. output point
Time period during which an invalid mea-
n
sured value is suppressed.
Baumer
Analog output
1
2
3
4
5
Hold Time
OM20/OM30 | V1
s