8.6

Switching points

Via the Switching points function, distances (switching points) are defined at which the switching
output is to be activated.
The function can be configured via the following parameters:
Select measurement mode (point mode or window mode).
n
Define the position of the switching points (SP1 and SP2):
n
▪ Point mode: SP1
▪ Window mode: SP1 and SP2
Point mode
1
0
Ill. 10: Sensor in the point mode measurement mode
Purpose/application (example):
n
▪ Quality control: Check the minimum/maximum height of a measurement object.
▪ Reach a desired position with a tool that edits an object.
Window mode
1
0
Ill. 11: Sensor in the window mode measurement mode
The smallest switching window is 2 mm.
n
Purpose/application (example):
n
▪ Quality control: Check the dimensions of a measurement object within a tolerance win-
dow.
IO-Link parameter: Switching points
Parameter name
SSC1 Config.Mode Disabled,
SSC1 Param.SP1
SSC1 Param.SP2
OM20/OM30 | V1
SP1
SP1/SP2
SP1/SP2
Values
Single
Point, Window
-
-
Description
Selecting the switching output mode:
n
▪ Point mode: (switching point SP1)
▪ Window mode (SP1 and SP2)
Distance at which the SSC1 is activated or inacti-
n
vated.
Distance at which the SSC1 is activated or inacti-
n
vated. Only relevant for window mode.
Operating Manual
Functions
|
8
29