Baumer SXC20 Benutzerhandbuch - Seite 20

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Digitalkamera Baumer SXC20 herunter. Baumer SXC20 48 Seiten. Sxc series cameralink cameras with truesense imaging sensors
Auch für Baumer SXC20: Schnellstart-Handbuch (2 seiten)

Baumer SXC20 Benutzerhandbuch
Figure 12 ►
Temperature measure-
ment points of Baumer 
SXC cameras.
20

Environmental Requirements

6.5.

6.5.1. Temperature and Humidity Range

Storage temperature
Operating temperature*
Housing temperature
**)***)
* For environmental temperatures ranging from (value A) to (value B), please pay atten-
tion to the max. housing temperature. The values are listed in the table below:
Caution
Provide adequate dissipation of heat, to ensure that the temperature does
not exceed +60°C (+140°F).
The surface of the camera may be hot during operation and immediately 
after use. Be careful when handling the camera and avoid contact over a 
longer period.
Storage and Operating Humidity

6.5.2. Heat Transmission

It is very important to provide adequate dissipation of heat, to ensure that the housing 
temperature does not reach or exceed +60°C (+140°F). As there are numerous possibili-
ties for installation, Baumer do not specifiy a specific method for proper heat dissipation, 
but suggest the following principles:
operate the cameras only in mounted condition
mounting in combination with forced convection may provide proper heat dissipation
*)
Please refer to the respective data sheet.
**) 
Measured at temperature measurement point (T).
***) 
Housing temperature is limited by sensor specifications.
*)
Temperature
-10°C ... +70°C ( +14°F ... +158°F)
+5°C ... +60°C (+41°F ... +140°F)
max. +60°C (+140°F)
Humidity
T
10% ... 90%
Non-condensing