Baumer SXC20 사용자 설명서 - 페이지 20
{카테고리_이름} Baumer SXC20에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer SXC20 48 페이지. Sxc series
cameralink cameras with truesense imaging
sensors
Baumer SXC20에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (2 페이지)
Figure 12 ►
Temperature measure-
ment points of Baumer
SXC cameras.
20
Environmental Requirements
6.5.
6.5.1. Temperature and Humidity Range
Storage temperature
Operating temperature*
Housing temperature
**)***)
* For environmental temperatures ranging from (value A) to (value B), please pay atten-
tion to the max. housing temperature. The values are listed in the table below:
Caution
Provide adequate dissipation of heat, to ensure that the temperature does
not exceed +60°C (+140°F).
The surface of the camera may be hot during operation and immediately
after use. Be careful when handling the camera and avoid contact over a
longer period.
Storage and Operating Humidity
6.5.2. Heat Transmission
It is very important to provide adequate dissipation of heat, to ensure that the housing
temperature does not reach or exceed +60°C (+140°F). As there are numerous possibili-
ties for installation, Baumer do not specifiy a specific method for proper heat dissipation,
but suggest the following principles:
▪
operate the cameras only in mounted condition
▪
mounting in combination with forced convection may provide proper heat dissipation
*)
Please refer to the respective data sheet.
**)
Measured at temperature measurement point (T).
***)
Housing temperature is limited by sensor specifications.
*)
Temperature
-10°C ... +70°C ( +14°F ... +158°F)
+5°C ... +60°C (+41°F ... +140°F)
max. +60°C (+140°F)
Humidity
T
10% ... 90%
Non-condensing