Baumer FLDK 110G1303/S14 Benutzerhandbuch - Seite 12

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kassenschalter Baumer FLDK 110G1303/S14 herunter. Baumer FLDK 110G1303/S14 35 Seiten. Laser copy counter

Baumer FLDK 110G1303/S14 Benutzerhandbuch
Nominal working distance h
Angular tolerance
Overlap orientation
Running direction
Front window
Manual SCATEC-2
Version 2021-09
FLDK...1003/...; FLDK...1303/...
FLDK...1005/...; FLDK...1006/...
The resolution is dependent on the distance. The highest resolution is
achieved at the nominal working distance. (See also Section 10.6 Specific
application data)
max. +/- 3°
The copies are counted when the edge facing the laser beam moves
through the beam. If an edge faces away from the beam, it is not detected.
Tail edges are therefore not counted unless they face upwards.
The SCATEC-2 permits both running directions. The edges facing the
laser beam (front edges) are detected by the sensor regardless of the
running direction.
The direct line of sight from the impact point
of the laser to the entire front window must
not be obstructed by any hardware in a
distance range
d = 0 – 80 mm
FLDK 110x1003/Sxx
FLDK 110x1303/Sxx
d = 0 – 120 mm FLDK 110x1005/Sxx
FLDK 110x1006/Sxx
If mountings or other components are close
to this zone for any reason, you should
consult a technician from Baumer electric.
www.baumer.com
40 mm above the conveyor belt
100 mm above the conveyor belt
12
d
Baumer Electric AG
Frauenfeld, Switzerland