WARNING
TURN OFF AGITATOR BEFORE ADDING
INGREDIENTS OR INSPECTING KETTLE
CONTENTS. DO NOT WEAR LOOSE
CLOTHING OR JEWELRY AROUND
OPERATING MIXER KETTLE. KEEP WELL
CLEAR OF ROTATING MIXER ARMS AND
PADDLES AT ALL TIMES.
WARNING
DO NOT PLACE HANDS, TOOLS, OR HOSES
IN KETTLE WHILE AGITATOR IS MOVING.
AGITATOR AREA MUST BE CLEAR OF
OBSTRUCTION BEFORE OPERATION.
6
OM-TDB-20/40, TA/2
After the mixer is installed, take the following actions to confirm that the equipment is
operating correctly.
1. Tilt the mixer through its complete tilting range to ensure that there is no hazard or
interference.
2. Make sure the agitator is properly coupled with its drive shaft. If the mixer has a
slip-on coupling, the drive pin must be positioned at the end of the J-slot.
3. When the mixer is in operating position, every scraper blade should touch the
inside of the kettle during at least part of each revolution of the agitator.
4. At the circuit breaker or fuse box, turn on the electric power supply to the mixer.
5. Switch on the drive and confirm that the mixer operates smoothly. For a variable
speed model, confirm that the mixer operates correctly throughout its speed range.
6. Make sure the agitator turns in the correct direction, so it pushes the nylon scraper
blades ahead of the agitator bar.
If the unit functions as described above, it is ready for use. If the unit does not function
as intended, call your local Groen authorized service agency.
For instructions on initial start-up of the kettle component of your cooker/mixer, see
the separate kettle manual.
Slip-On Coupling
TO RUN AGITATOR
1. Ensure kettle is fully upright.
2. Ensure mixer head is fully down and latched.
3. Set the speed dial to desired speed.
4. Turn the start switch to ON.
TO STOP AGITATOR
1. Turn the ON/OFF toggle switch to OFF.