Dover HYDRO HYDSPD0093M Benutzerhandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Controller Dover HYDRO HYDSPD0093M herunter. Dover HYDRO HYDSPD0093M 20 Seiten. With evoclean

Dover HYDRO HYDSPD0093M Benutzerhandbuch
3.OO programming (continued)
3.O6 Washer Extractor Parameters (continued)
6) Washing process: (continued)
7) Trigger mode – Sequential, Signal + 1st Phase, sequential + 1st phase or signal + repetition.
8) Finish mode – signal or pump. Choose whether you want the unit to end the program via a pump or signal (signal number,
i.e. final rinse, door lock etc).
9) Default formula after finish – choose a formula number for the unit to reset to after finish (0 will create the unit to not select a
formula).
10) Hold machine
Activation – choose from Not used if no machine hold is present, while queued (whilst waiting for dosage) or while
queued/ during dosage.
Delay – the Time the unit waits before activating the hold order. Commonly used to let the washer extractor gain some
level of water.
Timeout – max amount of time before the delay times out.
11) Click on Save at the bottom of the page.
3.O7 Formulas
1) Click on Formulas in the left-hand column, the page shown at the top of the next page will open.
2) Formulas
Formula – the number of the formula you want to program.
Last change – this shows the date the formula was last edited.
Name – the name of formula i.e. white bedsheets.
% of nominal load - % of load the unit will dispense chemical for.
3) Signal/phase
Product/pump - enter the product i.e. detergent.
g/kg – enter the amount you wish you dispense in grams per kilogram.
D – tick this box to add a delay.
Delay 1 – the time in which the whole phase is on hold before dosing any products (commonly used to allow the machine
to achieve a water level in the drum when the signal is activated from a fill valve).
Delay 2 – takes place after delay 1 has expired and will only be applied to products that have been activated with a tick.
The full sequence of leak test, water test, etc, will be applied before any dosing is achieved, even if a 1 second delay is set.
14