3.OO programming (continued)
3.O6 Washer Extractor Parameters (continued)
6) Washing process: (continued)
7) Trigger mode – Sequential, Signal + 1st Phase, sequential + 1st phase or signal + repetition.
8) Finish mode – signal or pump. Choose whether you want the unit to end the program via a pump or signal (signal number,
i.e. final rinse, door lock etc).
9) Default formula after finish – choose a formula number for the unit to reset to after finish (0 will create the unit to not select a
formula).
10) Hold machine
•
Activation – choose from Not used if no machine hold is present, while queued (whilst waiting for dosage) or while
queued/ during dosage.
•
Delay – the Time the unit waits before activating the hold order. Commonly used to let the washer extractor gain some
level of water.
•
Timeout – max amount of time before the delay times out.
11) Click on Save at the bottom of the page.
3.O7 Formulas
1) Click on Formulas in the left-hand column, the page shown at the top of the next page will open.
2) Formulas
•
Formula – the number of the formula you want to program.
•
Last change – this shows the date the formula was last edited.
•
Name – the name of formula i.e. white bedsheets.
•
% of nominal load - % of load the unit will dispense chemical for.
3) Signal/phase
•
Product/pump - enter the product i.e. detergent.
•
g/kg – enter the amount you wish you dispense in grams per kilogram.
•
D – tick this box to add a delay.
•
Delay 1 – the time in which the whole phase is on hold before dosing any products (commonly used to allow the machine
to achieve a water level in the drum when the signal is activated from a fill valve).
•
Delay 2 – takes place after delay 1 has expired and will only be applied to products that have been activated with a tick.
The full sequence of leak test, water test, etc, will be applied before any dosing is achieved, even if a 1 second delay is set.
14