TECHNICAL SPECIFICATIONS

Model:
Volts:
Amps:
Hertz:
Maximum Treatment Time:
Weight:
Length: (Inches)
Dimensions:
Width: (Inches)
Height: (Inches)
Lamp Model:
Number of Lamps:
Lamp Data:
Power Consumption:  (Watts/Lamp)
Ultraviolet Output:  (Watts/Lamp)
Average Effective Life: (Hours)
Wattage is lamp watts only and does not include ballast loss.
 Ultraviolet output at 254nm at 100 hours and 80°F (approximate).
All specifications, dimensional data, etc are approximate and subject to change without notice.

OPTIONAL ACCESSORIES

Germicidal Ultraviolet Detector: A sensitive, hand-held, self-contained battery operated ultraviolet meter
1.
Zenith
TM
that can be used for:
• Monitoring UV-C Germicidal Lamp Intensity & Aging
• Measuring UV-C Germicidal Fixture Leakage.
2. Promate
Safety Glasses: Safety eyewear MUST be used as general-purpose safety protection and for additional shielding
from ultraviolet rays
Additional Promate
3.
ultraviolet rays. One (1) face shield is included with purchase of Sanidyne
may be purchased.
4. Additional Promate
an ultraviolet sanitizer is in use and that the treatment area MUST not be entered. Two (2) warning signs are included with
purchase of Sanidyne
5.
UVC Dosimeter Card: Contains a patented colorimetric indicator that changes color at 25, 50, and 100 mJ/cm
that your Sanidyne
cycle; DO NOT reuse. Complete instructions for use are on back of card. One (1) card has been included with this purchase but
additional cards may be purchased by phone or on BuyUltraviolet.com. (See "Replacement Parts" on Page 17 for item number.)
For more information and purchasing contact our offices, weekdays between 8:30 am and 5:00 pm Eastern time, at:
Atlantic Ultraviolet Corporation
Tel: (631) 273-0500 • Fax: (631) 273-0771 • Email: [email protected] • Website: Ultraviolet.com – BuyUltraviolet.com
16
Table 2 – Technical Specifications
Face Shields: Lightweight visor with adjustable headgear provides eye and face protection from
Danger Signs: Laminated Danger Signs (8-1/2" x 11") to be affixed to entry door(s) to warn that
Prime Remote but additional signs may be purchased.
®
Prime Remote is achieving the desired UV-C exposure. Each card is designed for one (1) treatment
®
, 375 Marcus Boulevard, Hauppauge, New York, 11788
®
40-0634B
120v
4.5A
50/60Hz
24 Hours
31 lbs.
13-15/16"
12-1/8"
36-7/8"
05-0892
8
68.75W (550W Total)
17.8W (143W Total)
13,000
Prime Remote but additional face shields
®
40-0674B
220–240v
2.5A
50/60Hz
to visibly confirm
2