Daikin 2M56GV1G Service-Handbuch - Seite 15
Blättern Sie online oder laden Sie pdf Service-Handbuch für Kühler Daikin 2M56GV1G herunter. Daikin 2M56GV1G 19 Seiten. 5.6 kw class outdoor unit, removal procedure
Si11-990
3. Removal of Fan Motor
Procedure
Step
1. Removal of the outdoor
fan
1
Unscrew the nut (M6)
and remove the outdoor
fan.
2. Removal of the fan motor
1
Remove the 2 screws.
Remove the fan motor
stand ASSY.
2
Cut the clamps at 3
locations.
Remove the 4 screws.
3
Remove the fan motor.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Outdoor fan
Fan motor stand ASSY
Fan motor
Wrench size: 10mm
(R10799)
(R10800)
(R10801)
(R10802)
Removal of Fan Motor
Points
13