Annovi Reverberi Blue Clean 810 Produkthandbuch - Seite 9

Blättern Sie online oder laden Sie pdf Produkthandbuch für Hochdruckreiniger Annovi Reverberi Blue Clean 810 herunter. Annovi Reverberi Blue Clean 810 9 Seiten. Annovi reverberi power-jet cleaner product manual

12
English
6.3 Oil Change
Caution - Danger!
Spent oil must not be dumped because it is a
pollutant. It must be disposed of in accordance with
legal requirements.
Change pump and reduction gearbox oil (where fitted)
after first 50 hours of operation, and every 500 hours
thereafter.
Remove the casing (where fitted) to change the oil.
Replace the casing (where fitted) when done.
6.3.1 Changing the pump oil
Unscrew the drain plug and allow all the spent oil
to flow out.
Screw the plug back into place.
Pour in oil through the filler hole.
Check that the oil level is correct.
For oil characteristics, refer to the "Oil characteris-
tics" table.
6.3.2 Changing the reduction gearbox oil (where fitted)
Unscrew the drain plug and allow all the spent
oil to flow out.
Screw the plug back into place.
Pour in oil through the filler hole.
Check that the oil level is correct.
For oil characteristics, refer to the "Oil character-
istics" table.

TROUBLESHOOTING

7
Problem
Pump does not reach work-
ing pressure
Pressure drops during use
Water leakage
Cleaner noisy
Oil leakage
Engine malfunction
Water escapes from ther-
mostat valve
Possible causes
Nozzle worn
Water filter fouled
Water supply pressure low
Air being sucked into system
Air in pump
Adjustable nozzle not positioned correctly
Water intake from external tank
Intake water too hot
Nozzle clogged
Seals worn
Water too hot
Seals worn
Water temperature inside nozzle has exceeded
max. rated value stated on nameplate
Table 1 - Oil characteristics
Component
Pump 850
SAE 30 W
Pump 840
SAE 30 W
Pump 830
SAE 30 W
Pump 820
SAE 30 W
Pump 810
SAE 75 W90
Reduction
AGIP BLASIA W90
gearbox
6.4 Storage
Treat the appliance with non-corrosive, non-toxic anti-
freeze before storing it away for winter.
Replace nozzle
Clean filter (fig.5)
Turn on water supply tap fully
Check tightness of hose fittings
Switch off the cleaner and keep depressing and
releasing the gun trigger until the water comes out
in a steady flow. Switch the cleaner back on again.
Turn the adjustable nozzle "E" (+) (fig.3)
Connect cleaner to the mains water supply
Reduce temperature
Clean nozzle (fig.5)
Have the seals replaced at your nearest Authorised
Service Centre
Reduce temperature (see technical data
Contact your nearest Authorised Service Centre
Refer to the engine manufacturer's manual.
With appliance in operation, do not stop the water
jet for more than 5 minutes at a time
Oil type
Quantity (kg)
0.9
0.9
0.3
0.3
0.135
0.21
Remedy