Daikin ATM18MV2S Service-Handbuch - Seite 16

Blättern Sie online oder laden Sie pdf Service-Handbuch für Klimageräte Daikin ATM18MV2S herunter. Daikin ATM18MV2S 20 Seiten. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Auch für Daikin ATM18MV2S: Service-Handbuch (20 seiten)

Daikin ATM18MV2S Service-Handbuch
Indoor Heat Exchanger
Step
4
Slightly pull out the
auxiliary piping.
5
Unfasten the 2 hooks
on the left side.
6
Unfasten the 2 hooks
on the right side.
7
Pull the indoor heat
exchanger to the front
side, unfasten the
hooks completely, and
then remove the indoor
heat exchanger.
14
Procedure
Auxiliary piping
Hook
Indoor heat exchanger
Points
(R23430)
Hook
(R13231)
(R13232)
(R2802)
Removal Procedure
Si041254EE