DTC PB-5 Benutzerhandbuch - Seite 7

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Transmitter DTC PB-5 herunter. DTC PB-5 16 Seiten. Beacon transmitter

Test Push-button
Holding this push-button, while powering up, causes the unit to go into test mode.
Based on the break wire and standby wire inputs, the unit will go into one of the
four transmit modes.
Break wire
Standby wire
None
None
None
In
In
None
In
In
Init Push-button
Holding the init switch for one second, re-initializes the unit. It reads the mode/
channel switch and can be used to change the channel/mode without cycling the
power. The LED blinks once. If the init switch is held for more than 5 seconds, the
unit is switched to default mode. This is indicated by 5 LED blinks, a short delay,
and then one LED blink.
Tone: 1000 Hz on all channels
Default Confidence tone interval: 30 seconds
Battery Monitoring: Disabled
Standby: On closed on all channels
Break wire: Auto configured on all channels
RF Output
Connect the antenna to this connector.
RS232 Connector
The programming cable is connected to this connector when programming is
required.
Transmit Output
Continuous Tone
Continuous Tone
Tracking Pulses
Unmodulated Carrier
Default Settings:

CONNECTIONS

Channel/Mode switch
LED light
Test push-button
Init push-button
Antenna connector
Programming Cable Connector
DTC COMMUNICATIONS, INC.
7