5.3.3 Keypad functions
If timer is disabled (tF = OFF), key A and B control the SSR power output. Press
key A momentarily to enable the output, or restart from the STOP status. The
bottom display will show "RUN" for a short moment. Press key B momentarily
to stop the output. The bottom display will flash "STOP".
If timer is enabled (tF = ON), key A and B control the SSR power output and
timer function. Press key A momentarily to enable the output, or resume/restart
from the HOLD/STOP status. If PuS is set to "dely" (delayed power-up, note 2-
2 in page 4), timer will be enabled at the same time. Press key B momentarily
to hold the timer, but it will NOT hold the power output status. Press and hold
Key B for 5 seconds to stop the timer and disable the power output. Bottom
display will flash "STOP" and OUT indicator is OFF.
Note for mute function of Key A/RUN: Key A can also be used to mute the
built-in buzzer when triggered by temperature alarm (relay mode ALbE only, note
12 in page 9). Once the built-in buzzer is turned on (triggered by temperature
alarm), user can mute the built-in buzzer manually by pressing Key "A" (or "RUN")
momentarily. This mute operation will not affect relay action nor mute step/timer
event alarm notifications.
Key A can be used to start the program as well, but "mute" function has higher
priority than "start" function: When process temperature is in the alarm zone and
the program has not started yet, press Key A momentarily will mute the alarm
first. To start the program, you need to press Key A again.
5.3.4 Criterions to start the timer in boiling mode
To start the timer, three criterions need to be met:
1). Timer must be enabled in parameter settings: tF = ON (note 9 in page 7)
2). The controller cannot be under STOP/HOLD status. If you see the display
flashes "STOP" or "HOLD", you need to press key A momentarily to start or
resume the program.
3). Controller's reading temperature (top display) must be higher than the value
of btsp (boiling timer start temperature, note 9 in page 7).
80
100
Press down
Knob
and hold the
knob for 5s
goto
mash
Knob
goto
prog
Knob
goto
boil
Knob
goto
rely
Knob
goto
syst
Figure 5. Parameter group selection
2018.08
Knob
Enter Mash
mode settings
Press
Rotate
Enter Step
Knob
Program
Settings (Mash
Press
mode)
Rotate
Knob
Enter Boil
mode settings
Press
Rotate
Knob
Enter Relay
settings
Press
Rotate
Knob
Enter System
settings
Press
Tip 1: When timer is started, you will hear the beeping notification. Please see
section 9 in page 10 for details.
Tip 2: Similar to mashing mode, you can even hold the timer (by pressing key B
momentarily) before the timer is started (reading temp. is below btsp, note 9 in
page 7). Then when reading temp. is over btsp, timer will be started and held
immediately. You will hear the beeping notification. This tip can create one
"HOLD" step before the timer is started.
6. Control Parameters
Parameters are divided into five groups (figure 5): MASH for step mashing
control, PROG for step program settings for mashing, BOIL for boiling control,
RELY for alarm relay settings and SYST for system configuration.
To enter parameter setting mode, press and hold the knob for at least 5s. Then
you will see "GOTO" on the top display. Rotate the knob, you will see the bottom
display changes with five different names: MASH (figure 5), PROG (figure 8),
BOIL (figure 10), RELY (figure 11) and SYST (figure 6). All parameter values
are stored in the controller memory, and they remain unchanged if you power it
off.
Press down and hold the knob for 5s to enter the setting group selection. Bottom
display is your current selected group. Press down the knob again to enter the
selected parameter group. Then top display shows the current selected
parameter name, and the bottom display shows its value/options. Rotate the
knob clockwise to increase the value, and counter-clockwise to reduce the value.
Fast rotating will change the value rapidly. Once finished, press knob again to
confirm and go to next parameter. You can press the knob repeatedly to exit the
setting quickly.
6.1 System settings (SYST)
System parameters that configure this controller are grouped under this menu.
Table 1. System configuration parameters.
System Configuration (SYST)
Display
Code
Description
Pb
Temp. reading offset
Pb
C-F
Temp. display unit
C-F
pus
PuS
Power up settings
Temperature
reading offset
Temp. display
unit
Power up
setting
End
Figure 6. Flow chart of setting system parameters.
WWW.AUBERINS.COM
Setting
Initial
Remark
Range
Setting
-20.0 ~
0.0
Note 1
+20.0 ° C or ° F
° C, ° F
° F
Note 2-1
inst, dely
dely
Note 2-2
goto
syst
Knob
pb
0
Knob
C-f
f
Knob
pus
Dely
Knob
80
100