AUBER INSTRUMENTS
Table 3. Step program setting parameters
Step Program Settings for Mashing Mode (PROG)
Display
Code
Description
c-1
C-1
Step 1 set temperature
t-1
Step 1 time duration
t-1
C-2
Step 2 set temperature
c-2
t-2
Step 2 time duration
t-2
C-3
Step 3 set temperature
c-3
t-3
Step 3 time duration
t-3
c-4
C-4
Step 4 set temperature
t-4
t-4
Step 4 time duration
c-5
C-5
Step 5 set temperature
t-5
t-5
Step 5 time duration
C-6
Step 6 set temperature
c-6
t-6
Step 6 time duration
t-6
C-7
Step 7 set temperature
c-7
t-7
Step 7 time duration
t-7
C-8
Step 8 set temperature
c-8
t-8
t-8
Step 8 time duration
Note 6: Step program settings, C-1 ~ C-8, t-1 ~ t-8:
A total of 8 steps can be programmed in step mashing mode. Each step contains
the set temperature (C-X) and the time duration for this step (t-X), where "X" is
the step number (e.g. step 4 temperature is represented by C-4, and step 4 time
is represented by t-4). Time starts counting when the reading temperature is tSP
(section 6.2, note 3) degree below the set temperature in that step, and stops
counting once time is up. Then it will jump to next step. The time unit is
hour:minute (hh:mm) with 1 minute resolution. You can also set time to "hold",
or "stop" by keep turning counterclockwise, until the reading is below the zero.
The initial step program for mashing:
Table 4. Default step program settings.
Parameter
C-1
t-1
C-2
t-2
C-3
t-3
C-4
t-4
C-5
t-5
C-6
t-6
C-7
t-7
C-8
t-8
This program will control the temperature at 122F for 30 minutes. Then, change
the temperature to 140F and hold for 20 minutes. Then change the temperature
to 154F and hold for 40 minutes. Finally change the temperature to 168F and
hold for 15 minutes. Then end the program (timer is set to 0 for step 5 and 6).
2018.08
Setting
Initial
Remark
Range
Setting
0 ~ 999
122
hold, stop
00:30
0 ~ 99:00
0 ~ 999
140
hold, stop
00:20
0 ~ 99:00
0 ~ 999
154
hold, stop
00:40
0 ~ 99:00
0 ~ 999
168
hold, stop
00:15
0 ~ 99:00
Note 6
0 ~ 999
50
hold, stop
00:00
0 ~ 99:00
0 ~ 999
50
hold, stop
00:00
0 ~ 99:00
0 ~ 999
50
hold, stop
00:00
0 ~ 99:00
0 ~ 999
50
hold, stop
00:00
0 ~ 99:00
Initial Setting
122
00:30
140
00:20
154
00:40
168
00:15
50
00:00
50
00:00
50
00:00
50
00:00
Figure 8. Flow chart of setting step program settings.
6.3 Boiling Parameters
Parameters the configure the boiling control are grouped under this menu.
For the easy of discussion, we divide the boiling mode into two phases, the initial
heating phase and boiling phase. During the initial heating phase, power
output is set high to accelerate the temperature rise. During the boiling phase,
the power output is lowered to prevent the boiling over. We name the output
setting for the boiling phase as "Boil Output" setting. Its value is always
displayed on the bottom LED display and can be adjusted by turning the knob.
The acceleration power output setting is not displayed at bottom display during
initial heating, because it rarely set to less than 100%.
Table 5. Boiling mode parameters
Boiling Mode Parameters (BOIL)
Display
Code
Description
Boiling acceleration
bAST
bAST
set temp.
Boiling acceleration
bOUT
bOUT
output power
Total number of timer
nE
ne
events
Bot1
Bot1
Event 1 timer
Bot2
Event 2 timer
Bot2
Bot3
Event 3 timer
Bot3
Boiling timer start
btSP
btSP
temp.
Alarm duration for
AD
Ad
boil mode
Boiling ending
bEO
bEO
options
Timer function for
tf
tF
boil mode
Note 7: Acceleration heating function: bAST, bOUT
EZboil accelerates heating speed of the initial heating phase by running the
heater at high power, then reduce the power once the temperature is getting
close to the boil. The heating acceleration in boiling mode is controlled by two
parameters, Boiling acceleration set temperature, bAST and Boiling
acceleration output power, bOUT. The bAST set the temperature limit that
below this temperature, the controller will output at a power determined by the
bOUT. When temperature rise to the bAST, the output will automatically reduce
to a lower level to prevent a messy boiling over. The boiling over is caused by
several factors including the amount of foam on the surface and the power of the
WWW.AUBERINS.COM
Initial
Setting Range
Remark
Setting
-999 ~ +9999° C
200
or ° F
Note 7
0 ~ 100%
100
1 ~ 9
3
0 ~ 99:59
01:00
Note 8
0 ~ 99:59
00:20
0 ~ 99:59
00:01
-999~+9999 ° C
208
Note 9
or ° F
0 ~ 200
10
Note 10
ON, OFF
OFF
Note 9
ON, OFF
ON
Note 9
P6/14