Danfoss APP 0.6 Service-Handbuch - Seite 4

Blättern Sie online oder laden Sie pdf Service-Handbuch für Water Pump Danfoss APP 0.6 herunter. Danfoss APP 0.6 12 Seiten. Disassembling and assembling
Auch für Danfoss APP 0.6: Gebrauchsanweisung (8 seiten)

Danfoss APP 0.6 Service-Handbuch
Disassembling and Assembling, APP 0.6-1.0
Service guide |
4 | 180R9092 | DKCFN.PI.013.EC5.02 | 521B0739
7. Remove the cylinder barrel.
9. Gently lever the valve plate assembly free
with the aid of a screwdriver.
11. Gently press, by hand, the valve onto the
cylinder barrel.
8. Remove the port plate and guide pin.
Mount backup
ring first
Then mount
O-ring
10. Replace the O-rings and the back-up rings
on the valve plate. Mount the new back-
up rings on the new valve plate first and
then mount the new O-rings.
Wet the O-rings and back-up rings with
clean (filtered) soap water.
12. Position the port plate over the guide pin.
IMPORTANT: Make sure that the guide
pin is located in the locating hole in the
port plate
© Danfoss | DCS (im) | 2017.08
Locating hole
Guide pin