LOAD_UNBALANCE_ENABLED: 40402
The address contains the status of the Load unbalance function:
•
0 = disabled
•
1 = enabled
To enable this parameter, you can connect to the wallbox following the procedure described
in this manual in the Configuration chapter. This function is enabled only if the wallbox is
connected in three-phase configuration:
•
Enter the Setting section
•
Select the register 3 – Load unbalance en.
•
Set the register equal to 1 to enable the load unbalance function, or 0 to disable it
•
The new settings are automatically saved
LOAD_UNBALANCE_CURRENT: 40403
The address is used to set the current for the load unbalance function. It contains the maximum
allowable current unbalance between the phases. This function is enabled only if the wallbox is
connected in three-phase configuration
The default value is set to 32000 mA
To modify this parameter, you can connect to the wallbox following the procedure described in
this manual in the Configuration chapter:
1.
Enter the Setting section
2.
Select the register 4 – Load unbalance val.
3.
Set the new value of current in mA in the register
4.
The new settings are automatically saved
ON_OFF_INPUT: 40406
The address is used to enable or disable the charging station:
•
0 = charging station disabled (stuck in C1 or B1 state when the user plug the charging
cable or during the charging phase)
•
1 = charging station enabled (according to standard IEC 61851 State Machine)
MODBUS RTU
C o n f i g u r e a t i o n G u i d e
10