Danieli Automation ID2202 Handbuch für Installation, Gebrauch und Wartung - Seite 4

Blättern Sie online oder laden Sie pdf Handbuch für Installation, Gebrauch und Wartung für Sicherheitssensoren Danieli Automation ID2202 herunter. Danieli Automation ID2202 20 Seiten. Infrared photodetector

Danieli Automation ID2202 Handbuch für Installation, Gebrauch und Wartung
Danieli Automation – ID2202
3

DESCRIPTION

3.1
E
XTERNAL APPEARANCE
The container of photodetector ID2202 (1), made of pressure-cast aluminium, is equipped with a semi-
circular support plate (2) that allows its fastening and orientation on the vertical plane within an angle of
about 30° , and incorporates a circuit for liquid co oling (3), to be supplied with water or other
refrigeration fluids based upon the working environmental conditions.
There is an optical window (4) on the front side through which the IR sensor inside the HMD "observes"
the material to detect.
A green LED, that is inside the HMD, can be seen through the optical window.
On the rear side of the photodetector there are the following connection and signalling devices:
bayonet connector, 6 contacts, directive MIL-C-5015 (5)
two-colour red/green LED (6)
potentiometer to adjust sensitivity (7)
1/4" GAS threads to supply and drain the cooling circuit (8).
26
Certified by OneDoc A.620.107 Rev.04-MU 27/145 #1061394
Danieli Automation Standard - Installation Use and Maintenance Manual - ID2202
2. Exterior appearance
3. Rear view