CONTACLIP 16099.2 Schnellstart-Handbuch

Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für E/A-Systeme CONTACLIP 16099.2 herunter. CONTACLIP 16099.2 4 Seiten. Gsm controllable i/o module

CONTA-ELECTRONICS
=====GSM controllable I
=====
=====
=====
GSM controllable I/ / / / O module
O module
GSM controllable I
GSM controllable I
O module
O module
Electrical specifications
Electrical specifications
Electrical specifications
Electrical specifications
=
Order Information
Order Information
Order Information
Order Information
type
Cat. no.
Weight
Input / Output Data
Input / Output Data
Input / Output Data
Input / Output Data
* of measured value
8 multifunctional analog / dig. inputs
resolution / accuracy (0..10V)
input resistance (0..10V)
input current digital inputs (typ.)
UI minimal pulse length
input threshold digital Inputs
4 relay outputs
rated / inrush current (Ohmic load)
max. power rating
life span @ Ohmic load
max. switching frequency
contact material / test voltage
GSM Data
GSM Data
GSM Data
GSM Data
Frequency
Sensitivity
Transmit power
Antenna
General Data
General Data
General Data
General Data
module power supply
module current (max)
Reference out
Power Backup
operating / storage temperature
Max. relative humidity
CE marking
conductor cross section / strip length
mounting / installation position
module size LxWxH (TS 35 / direct)
insulating material / flammability class
protection degree (DIN 40050)
installation guidelines
Accessories
Accessories
Accessories
Accessories
GSM antenna
Cat.no.
Cat.no.
Cat.no.
Cat.no.
GSM external antenna
Cat.no.
Cat.no.
Cat.no.
Cat.no.
USB programming cable
Cat.no.
Cat.no.
Cat.no.
Cat.no.
GSM-PRO.dab.xls 25-11-2011
GSM-PRO quick start guide rev1 _EN.doc
=====
=
=
GSM-PRO
16099.2
275gr
0..10V / 24VDC (4..30VDC)
20mV / ±(20mV+0,3%*)
46kOhm
@10V: 0,3mA / @24V: 0,8mA / @30V: 1,0mA
800ms (while not transmitting)
Low < 2V / High > 4V
4 x CO Contact, 250 V ~
5A / 5 A
1200VA at 240V AC, 5A
5
Electrical: at max. load: > 1,5 x 10
cycles.
Mechanical: 15 x 10
-1
-1
6 min
at rated current, 1200 min
at no load
AgNi / 4kV
850/900/1800/1900 MHz
–108 dBm @ 850/900MHz / -107dBm @ 1800/1900MHz (typical)
Class 4 (2W@850/900 MHz), Class 1 (1W@1800/1900 MHz)
50 Ohm impedance, SMA connector
10..30V DC
275 mA DC @ 24V DC
4,7V ±10% / 20mA
Internal maintenance free supercap
-20°C...+50°C / -20°C...+70°C
80%, non condensing
Low Voltage Directive (LVD) 2006/95/EC, according requirements of EN 50178
EMC Directive 2004/108/EC, according requirements of EN 55011 and EN 61326-1
R&TTE 1999/5/EC according requirements ETSI EN 301-511 V9.0.2
0,2 - 2,5 mm² screw clamp connection / 6mm
DIN-rail TS35 or direct mounting / any
88 x 95 x 60 / 58 mm (without antenna)
Housing: noryl. Terminals: polyamid 6.6 V0 / UL94-V0
IP 20
for mounting-, wiring- and installation instructions, see Manual
GSM-antenna
16101.2
16101.2
16101.2
16101.2
GSM-antenna-external-SMA-2,5m
16061.2
16061.2
16061.2
16061.2
GSM-USB-cable
16103.2
16103.2
16103.2
16103.2
=
Further information:
=
=
=
Quick Start Guide
Quick Start Guide
Quick Start Guide
Quick Start Guide
=
=
=
6
cycles
=
Features:
Features:
Features:
Features:
• 8 multi-functional analog/digital inputs: 0..10V, 24VDC
• 4 relay outputs CO contact 250V/5A
• LED status indication for all I/Os
• SMS / E-mail status report for all I/Os
• SMS control for all outputs
• SMS / E-mail notification on status change at inputs
• SMS notification on power loss
• SMS / E-mail notification on power up
• Easy to use PC configuration program
www.conta-clip.com
Cat. No.: 95121.5
=
=
=
=
=
The GSM-PRO is a compact remote telemetry and control
system.
The various I/Os are monitored and controlled by SMS / E-
mail communication through the GSM network.
Every defined input status change (digital) or reached level
(analog) sends a SMS / E-mail notification to a selected
group of users. The outputs are set by simply sending an
SMS to the GSM-PRO.
I/Os are defined by an easy to use PC configuration
program.
=
=
Further information:
GSM- - - - PRO
GSM
GSM
GSM
PRO=
PRO
PRO
www.conta-clip.com