Wiring for ST-110 Serial Numbers 2725 and above
An excitation voltage of 2.5 V DC is recommended to minimize self-heating and current drain, while still
maintaining adequate measurement sensitivity (mV output from thermistor per C). However, other excitation
voltages can be used. Decreasing the excitation voltage will decrease self-heating and current drain, but will also
decrease thermistor measurement sensitivity. Increasing the excitation voltage will increase thermistor
measurement sensitivity, but will also increase self-heating and current drain.
Wiring for EE08-SS
*For more information, please see the EE08-SS manual:
Red: Excitation channel (excitation for
thermistor)
White: Single-ended channel (positive thermistor
lead)
Black: Ground (negative thermistor lead)
Clear: Shield/Ground
Red: Input voltage (7 to 30 V DC)
Black: Ground
Green: Single-ended channel (signal output by
air temperature sensor)
Clear: Ground (shield)
White: Single-ended channel (signal output by
relative humidity sensor)