Apollo Sprayers T6000 Gebrauchsanweisung - Seite 10
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Körperpflegeprodukte Apollo Sprayers T6000 herunter. Apollo Sprayers T6000 11 Seiten. Mist applicator
a. T100 Turbo unit turned ON. Air blows out of T6000 Mist applicator?
b. This is correct. Air blows constantly when Turbo unit is ON.
c. T100 Turbo unit turned ON. Unit does not operate or blow air?
d. Check that the unit is plugged in to proper electric source. Be sure there is power at the electric source.
e. If there is no problem with electric supply, call for technical support.
f. T100 Turbo unit is turned ON, the trigger is pulled back on Mist applicator, but no solution comes out?
g. Check that the cup is screwed firmly to Mist applicator.
h. Check that there is no solution bubbling or leaking around the cup.
i. Turn T100 Turbo unit OFF. Unscrew cup. Be sure that Solution Tube and Disc (#14) is connected and
has not come loose. Locate the two small holes in the Disc around the Solution tube. Be sure that these
two small holes are not clogged with dried solution. To clean, carefully insert a pin through each hole
ensuring that they are clear.
j. Turn T100 Turbo unit OFF. Remove air cap ring, Remove air cap, Remove Air Distributor Plate. Remove
Solution nozzle (#3) with an adjustable wrench or spanner. There is a Solution nozzle gasket (#4) on the
Solution nozzle. Do not lose it. Rinse Solution Nozzle under running water and check for dried solution
that may have blocked the hole. Reinstall Solution Nozzle Gasket. Reinstall Solution Nozzle, Air
distributor plate, air cap and air cap ring. Try spraying again. If you still have a problem call for technical
support.
k. Solution leaks in front of trigger.
l. With an adjustable wrench or spanner tighten Solution Needle Packing Screw (#7). Do not over tighten.
This can cause Solution needle to stick and not spring back. Try spraying again. If leaking continues the
Solution Needle Packing needs to be replaced. (Rare). Remove Solution Needle Packing Screw (#7).
Pry out the Solution Needle Packing's (4). Replace. Reinstall Solution Needle Packing Screw. Tighten
all the way, and then back off slightly. (1/8 turn) Test mist applicator for leakage. If you still have a problem
call for technical support.
m. When T100 Turbo unit is ON, Solution continues to spray from Mist applicator without trigger being pulled.
n. Immediately turn T100 Turbo unit OFF.
o. Disconnect mist applicator from air hose.
p. Slightly adjust (loosen) Solution Needle Packing Screw (#7). Test to see if problem is resolved.
q. Check to see that Needle Spring is installed. (#9). Remove Solution Flow Screw (#10). Look for Needle
Spring around the back of the Solution Needle. (See diagram). If lost, call for replacement.
r. Check Solution nozzle. Remove and clean following directions 9.c.iv. above.
s. Solution leaks around the top of the cup.
t. Make sure the cup is screwed firmly to the body of the Mist applicator.
u. Make sure the threads around the cup are clean and the threads inside the cup top assembly are clean.
v. Replace the cup top gasket. Pry out old gasket. Install new gasket. Test mist applicator.
10