1. It is VERY important to clean your Mist Applicator daily.
2. At the end of the day or when the equipment will not be used any more, disconnect the Mist Applicator
from the air hose.
3. Carefully unscrew the cup. If there is remaining solution, either close the cup with a cup lid, or pour the
remaining solution into a proper storage container.
4. Rinse the cup under warm running water until clean.
5. Fill the cup about ¼ full with water. Reconnect Mist Applicator to Air Hose. Turn on the T100 Turbo
Unit. Direct the Mist Applicator to a safe area and spray the clean warm water through the Mist
Applicator until the cup is empty.
6. Turn off the T100 ™Turbo Unit. Disconnect the Mist Applicator. Unscrew the cup.
7. Wipe all exposed areas dry.
8. Unscrew and remove the Air Cap Ring (#1). Rinse the threads under warm running water. Wipe the
threads clean and dry. Add a small amount of Mist Applicator lube to the threads.
9. Remove the Air Cap (#2). Rinse under warm running water. Wipe, clean and dry.
10. Remove the Air Distributor Plate (#5). Rinse under warm running water. Wipe clean, dry and lubricate
with Mist Applicator lube.
11. Reinstall the three pieces you just removed by reversing the removal procedure. Your Mist Applicator
should be ready for the next use. Store the Mist Applicator ™ in the holder on the T100 Turbo Unit.
12. The Solution nozzle (#3) can be removed for additional cleaning if necessary. We suggest doing this
at least once a week or more if you are using the Mist Applicator Daily. Be careful. There is a
Solution nozzle gasket (#4) around the threads of the Solution nozzle. Be sure to reinstall or leakage
will occur. Removal of the Solution nozzle is not necessary on a daily basis. You should however
remove it once a week and rinse under running water. The Solution nozzle can be easily removed
with an adjustable wrench or spanner. Place the tip of your adjustable wrench or spanner on the two
flat areas of the nozzle and twist anti or counter clockwise.
13. The Solution needle (#10) can also be removed for additional maintenance. To remove: Turn the
Solution Flow Screw anti or counter clockwise until it comes out of the Mist Applicator. Be careful
when removing the Solution Flow Screw as there is a small spring (#9) around the needle. Do not
lose it. This is important to the operation of the Mist Applicator. Set the spring aside and pull the
trigger all the way back until you can grab the needle with your finger tips and pull it out from the
back of the Mist Applicator. Once removed, rinse under warm running water, Clean and dry.
Reinstall reversing the removal procedure. NOTE: Occasionally it is necessary to lubricate the
needle (#10) where it slides through the gland nut (#7). Simply rub a few drops of Mist Applicator
lube around the needle shaft and reinsert into the back of the Mist Applicator.