elsner elektronik WS1000 Style Erste Schritte

Blättern Sie online oder laden Sie pdf Erste Schritte für Kontrolleinheit elsner elektronik WS1000 Style herunter. elsner elektronik WS1000 Style 2 Seiten. Connect control system
Auch für elsner elektronik WS1000 Style: Erste Schritte (2 seiten), Kurzanleitung (2 seiten), Handbuch (2 seiten), Montageanleitung (2 seiten), Handbuch (20 seiten), Kurzanleitung (2 seiten)

elsner elektronik WS1000 Style Erste Schritte
EN
WS1000 Connect controls:
First steps
Article numbers
60241-60246
The manual with additional information about commissioning,
functions and use of the controls WS1000 Connect can be
downloaded from www.elsner-elektronik.de in the menu area
"Service/Downloads".
1.
Description
The various technical facilities installed in the building are controlled automatically
and operated manually using the WS1000 Connect controls. In order to be able
to set up the system flexibly, both cable connections and wireless channels are
available.
The WS1000 Connect is delivered as a set, which includes the sensors needed
for room climate and weather data as well as the central unit (display with control
electronics). The sensor values are shown in the display and are the basis of the
automatic controls.
Functions and properties of the central unit WS1000 Connect:
Colour touch display 10.1 inch, for manual operation, system set up and
for setting the basic and automatic functions
Network connection by LAN or WLAN
Browser for viewing websites, streaming, etc.
Remote access via network for system setup, diagnostics etc. Approval by
the user required
Slide show from SD card as screen saver
Data storage on SD card (storage of settings)
Integrated loudspeaker (4 tweeters, 1 broadband speaker)
Motor outputs (4-10 pcs, depending on model) for electrically powered
- Awnings, blinds, shutters
- Windows, sliding roofs and sliding doors
4 multifunction outputs for
- Lights (switching or dimming)
- Heating (on/off), cooling (on/off), ventilators (on/off)
- Alarms
- Gutter heating
16 scenes for calling individually set movement positions and switch states
With a scene, several motors and devices are addressed simultaneously so
a suitable ambience is created with one press of a button ("TV", "Eating",
etc.).
4 multifunction inputs for
- Motion detector:
- Smoke detector:
- Climate detector (prevent ventilation if external
air-conditioning/heating is active)
- Safety contact (motors in safe position,
prevent exhaust air, start incoming air)
- Impulse for automatic reset
- Binary contact for free use
10 key inputs for additional conventional wind sensor for operating
motors and devices on site
32 radio channels for devices with Elsner RF radio protocol
- Sensors WGTH-UP for room temperature, humidity (from version 1.3),
WG AQS/TH-UP for room temperature, humidity, CO
WGT (indoor temperature) for measuring at other locations in the room
- Remote control Remo 8 (from version 1.8), Remo pro
- Sensor Corlo P RF, sensor interface RF-B2-UP
- WL400, WL800 and WL-Z ventilation units
- RF-VM ventilation module for connecting fans/circulation air heaters
from other manufacturers
- Wireless relay RF relay for on/off (each from version 5.5),
Heating module RF-HE-ST (from version 5)
- Wireless motor control device RF-MSG for up/down (from version 3.7)
- RF-L wireless dimmer:
The wireless actuators with a production date after 14.01.2016 are compatible with
the WS1000 Connect system. The production date can be found as part of the
serial number which has the following structure "DD MM YY consecutive number".
WARNING!
The radio transmission takes place over a non-exclusively
available transmission channel!
The device is not suited for applications outside the field of safety
equipment, such as emergency stop and alarm equipment.
Functions and properties of the indoor sensor:
Temperature measurement
Humidity measurement
Functions and properties of the weather station:
Brightness measurement (sun sensor)
Temperature measurement
Wind speed measurement
Precipitation detection
GPS receiver for date/time and installation coordinates (for sun position
calculation)
Overview of connection and control options
Weather
Indoor
Station
Sensors
Drive
Outputs
• Awning
• Blind
• Roller Shutter
• Window
• Sliding Door
Scope of delivery
Central control and operating unit with flush installation box and installation
accessories
Weather station with connection accessories
Indoor sensor with frame
(In addition, you need a device socket ø 60 mm, 42 mm deep)
2.
Commissioning
Installation notes
Installation, testing, operational start-up and troubleshooting should
only be performed by an electrician.
DANGER!
Risk to life from live voltage (mains voltage)!
There are unprotected live components within the device.
VDE regulations and national regulations are to be followed.
Ensure that all lines to be assembled are free of voltage and take
precautions against accidental switching on.
Do not use the device if it is damaged.
Take the device or system out of service and secure it against
unintentional use, if it can be assumed, that risk-free operation is no
longer guaranteed.
The device is only to be used for its intended purpose. Any improper modification
or failure to follow the operating instructions voids any and all warranty and gua-
rantee claims.
,
2
After unpacking the device, check it immediately for possible mechanical damage.
If it has been damaged in transport, inform the supplier immediately.
The device may only be used as a fixed-site installation; that means only when as-
sembled and after conclusion of all installation and operational start-up tasks and
only in the surroundings designated for it.
Elsner Elektronik is not liable for any changes in norms and standards which may
occur after publication of these operating instructions.
Procedure for commissioning
1. The installation of the controls and the sensors must be performed by a skilled
electrician. Information in the installation instructions, for example also about
the installation location, must be observed.
2. After completing the installation work, the controls must be thoroughly set up
in the menu System > Installation. Which connections are used for which func-
WS1000 Connect controls • from software 01.08 • Version: 03.09.2019 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250
WS1000 Connect controls
4 Multifunctional
Inputs
• Motion Detector
• Smoke Detector
• Climate Signaller
(Status heating/cooling)
10 Buttons
Wireless
• Security Contact
• Single Manual Button
Remote Control
• Impulse (for automatic reset)
Button
• Double Manual Button
Internet
Central
(W)LAN
App
Wireless
4 Multifunctional
Actuators
Wireless
Outputs
(Relay, MSG,
Ventilation Units
Dimmer)
• Heating
• AC/Cooling
• Light
• Dimmer
• Supply Air
• Alarm System
• Gutter Heating
tions, e.g. Motor 1 = Awning, is specified here.
See manual chapter Basic setting.
3. More settings for time reception, screen saver, network connection, access
code, updates, etc. can be made at any time in the menu System > WS1000 set-
tings.
See manual chapter Basic setting.
4. The automatic functions must be adjusted in the menu System > Automatic
settings to the structural conditions and individual requirements of the users.
See manual chapter Automatic.
Operating system
The WS1000 Connect works with the Android operating system. However, the
controls work self-sufficiently and therefore no third-party Apps may be installed!
Protective film
Remove the protective film from the display.
3.
Overview of homepage, navigation
With the WS1000 Connect controls you can control the connected technology
centrally, e.g. raise and lower shades, switch devices on and off and dim lights. All
the settings are also made on the display.
Top menu bar
Menu
Bottom navigation menu
Top menu bar:
The Internet browser (open website) and Volume functions can be accessed at any
time via the top menu bar. Time and date are displayed. Additionally, the start key
for the slide show appears here as soon as an SD card with pictures is loaded.
Menu on left (Start menu):
The menu on the left-hand side contains the System menu, with which you can re-
ach all the basic and automatic settings.
Connected motors and devices are operated by hand using the Manual menu.
This includes the selected Favourites for manual operation and the websites saved
as Bookmarks.
So that a motor/device is displayed in the Manual menu and/or as a Favourite, the
display has to be activated in the setting "Manual menu" in the installation settings.
 System > Installation > Motor/Multif.output > Manual menu
Right-hand display and settings area:
The control unit displays the current weather data as its start page .
The functions / parameters are displayed here when navigating in the settings
(submenus).
Bottom navigation menu:
On the bottom edge of the display you will see a Navigation menu with "Back"
arrow and a circle, which takes you back directly to the start page. Stay longer on
the circle to activate the screen saver.
Move motors and switch devices
Additional information about the display and control possibilities is contained in
Operation.
Example: Move blinds manually
 Start menu > Manual
Sliding bar position
Selecti-
on
Example: Switch light
 Start menu > Manual
1
Display
and
setting
area
Position
informa-
tion
Control
buttons
DBEEA6096