C.

Before starting the machine

1. Ensure machine is level
2. Turn on water supply.
3. Pull gun trigger until water starts to flow in a steady
steam then release trigger.
D.

Starting the electric motor

1.Turn on the motor
2.Check that there are no leaks in the line
connections, gun or lance. Pressure begins with the
gun trigger is squeezed.
KEEP THE MACHINE OUT OF
MOISTURE LADEN ATMOSPHERES
E.

Pressure washing

WEAR PROPER FACE PROTECTION WHEN
OPERATING PRESSURE WASHER!
1.
For high pressure jetting the black plastic lance
head should be pushed fully in. Rotate the plastic
head to adjust the angle of the spray jet.
2.
When low pressure and high flow is required,
including detergent application, pull the plastic
lance head out until it clicks
NOTE: Check the system for water leaks, oil leaks,
hose kinks, etc. Correct any problems before
proceeding.
Machine is now ready for operation.
Aussie Monsoon Single Phase Blasters ... Operation & Maintenance Manual
8
WARNING .... DO NOT RUN EXCESSIVE BY-PASS
SWITCH MACHINE OFF WITHIN TWO MINUTES OF
CEASING OPERATION AS EXCESSIVE BY-PASS CAN
CAUSE HEAT BUILD UP IN PUMP AND SUBSEQUENT
DAMAGE.
EXCESSIVE BY PASS RUNNING VOIDS WARRANTY!!
F.

Applying detergent

1.
Prepare pressure washer detergent solution as
required by manufacturer.
2.
Place detergent siphon tub/filter into solution.
3.
Adjust lance to low pressure setting.
4.
Apply cleaning solution to a dry surface, starting
at lower portion of areas to be washed and work
upward, using long overlapping strokes.
5.
Allow time to detergent to activate and then rinse
off. DO NOT allow detergent to dry on.
IMPORTANT;
You must flush the injection system after each use by
placing siphon hose into a bucket of clean water, then
run pressure washer in low pressure for 2 minutes.
March 2018