Cookson FDO-A10E Benutzerhandbuch - Seite 7

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Türöffnungssystem Cookson FDO-A10E herunter. Cookson FDO-A10E 19 Seiten. Industrial duty fire door operator

MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS
BEFORE PROCEEDING WITH ADJUSTMENTS. MAKE SURE OPENING AND THE AREA NEAR
DOOR/OPERATOR AND MECHANISMS ARE CLEAR OF OBSTRUCTIONS AND PERSONNEL.
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT
ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS.
1) To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment,
release plate and ensure it seats fully in slots of both nuts.
2) To increase door travel, spin nut away from actuator. To decrease door travel, spin limit
nut toward actuator.
3) Adjust open limit nut so that door will stop in open position with the bottom of the door
even with top of door opening.
4) Repeat Steps 1 and 2 for close cycle. Adjust close limit nut so that actuator is engaged
as door fully seats at the floor.
5) Connect Photo Electric Sensors per the wiring diagram on page 10 and test operation.
6) Connect sensing edge to controller terminals 3 & 10 and test operation - if equipped.
OPEN LIMIT SWITCH
RETAINING
PLATE
9001(7) ECN 1057 4/10/010

LIMIT SWITCH ADJUSTMENT

WARNING
LIMIT NUTS
CLOSE LIMIT SWITCH
7