4. Disarm the System.
To Initiate A Panic Alarm (at any timej:
1. a. Depress a remote panic switch momentarily, or
b. At No. 4021, depress optional POLICE PANIC switch momentarily, or
/-7
c. Remotely or at No. 4021, depress
l
and # keys simultaneously on No. 5240 momentarily:
Immediately, a loud, warbling siren will sound (if panic was selected as audible), the GREEN Loop Status LED on
the No. 5240 will be turned off and the panic supplemental output trigger will activate.
2. To reset, enter the arm/disarm code at the No. 5240.
To Manually Initiate a Fire Alarm (at any time):
1. a. Depress a remote open circuit fire panic switch, or
b. At No. 4021, depress optional FIRE PANIC switch momentarily, or
c. Push FIRE TEST/RESET switch upward, momentarily, at the No. 1021/4021.
Immediately, a loud steady siren will sound, the RED FIRE LED will light steady and the fire supplemental output
trigger will activate.
2. To reset, push FIRE TEST/RESET switch downward, momentarily at the No. 1021/4021.
Audible and Visual Indications:
LOUD STEADY SIREN INDICATES FIRE ALARM. EXIT IMMEDIATELY. CALL FIRE DEPARTMENT. FIRE LED on
No. 1021/4021 will be lit. To silence
and
reset after source of alarm eliminated, operate FIRE RESET switch. The Fire
Alarm will also be silenced when the automatic alarm cutoff period expires if not previously silenced manually.
LOUD WARBLING SIREN: A) DURING DAY (SYSTEM DISARMED) INDICATES AUDIBLE PANIC ALARM, B)
DURING NIGHT (SYSTEM ARMED) INDICATES BURGLARY ALARM OR AUDIBLE PANIC ALARM. Appropriate
ZONE LED(s) will be lit. The alarm will silence when the automatic alarm cutoff period expires or when the system is dis-
armed, whichever occurs first.
LOW LEVEL PULSATING SOUND FROM No. 5240's BUZZER INDICATES FIRE SYSTEM ZONE TROUBLE. FIRE
LED on No. 1021/4021 will be flashing. When the trouble is cleared, the sound will be silenced and the FIRE LED
will go out.
STEADY LOW LEVEL SOUND FROM No. 5240's BUZZER SOUNDS DURING ENTRY DELAY PERIOD.
r7 ',
STEADY LOW LEVEL BUZZ AT ARMING (LASTING FOR 3 SECONDS) INDICATES THAT SYSTEM HAS A
FAULTED ZONE. AT THE END OF THIS PERIOD, THE SYSTEM WILL REVERT TO THE DISARMED STATE.
.
TURNING SYSTEM OVER TO SUBSCRIBER:
1. Fully explain the operation of the system to the subscriber by going through each of the features as well as
the OWNERS MANUAL supplied.
2. Describe to him the operation of each zone. Clarify which zones are used at night and which contacts or
devices are connected into the INTERIOR ZONE.
3. Encourage him to find and remedy his own bad loop when setting the alarm. Show him how to bypass the
Interior Zone by using the "0" key on the.No. 5249.
GENERAL SPECIFICATIONS:
Physical:
No. 1021
No. 4021
wklth:
p" (20.3 cm)
11 n (27.9 cm)
Height:
15" (28.1 cm)
8" (20.3 cm)
Depth:
3" (7.6 cm)
3" (7.6 cm)
Electrical:
Voltage: 12V. AC (from No. 1322 Plug-In Transformer)
Current (per loop): 4 ma
Maximum Permissible Resistance (per loop): 309 Ohms (plus 1000 ohm end-of-line resistor, where used.)
Siren Driver Load: 8 ohms minimum (6 Watt minimum speaker rating)
Fuses: One 3 Amp fuse (No. 90-12) for fire and auxiliary power.
One 1 Amp fuse (,No. 90-17) for siren speaker power.