Dynabrade Dynafile 14000 Handbuch für Sicherheit, Betrieb und Wartung - Seite 2
Blättern Sie online oder laden Sie pdf Handbuch für Sicherheit, Betrieb und Wartung für Werkzeuge Dynabrade Dynafile 14000 herunter. Dynabrade Dynafile 14000 12 Seiten. 20,000 rpm / versatility kit
Auch für Dynabrade Dynafile 14000: Handbuch für Sicherheit, Betrieb und Wartung (12 seiten)
• Keep hand and clothing away from working end of the air tool.
Operation: Be sure that any loose clothing, hair and all jewelry is properly restrained.
• Secure inlet bushing on air tool with a wrench before attempting to install the air fitting to avoid damaging housing assembly.
• Check tool RPM (speed) with tachometer with air pressure set at 90 PSIG while the tool is running. If tool is operating at a higher speed than the RPM marked on the tool
housing, or operating improperly, the tool must be serviced and corrected before use.
Caution: Tool RPM must never exceed abrasive/accessory RPM rating. Check accessory manufacturer for details on maximum operating speed or special
mounting instructions.
• Disconnect air hose from tool when changing belts and contact arms.
• Connect air tool to power source. Be careful NOT to depress throttle lever in the process. Do not expose air tool to inlet pressure above 90 PSIG or (6.2 Bars).
Caution: After installing the accessory, before testing or use and/or after assembling tool, the Dynafile
Gradually increase tool speed. DO NOT USE if tool vibration is excessive. Correct cause, and retest to insure safe operation.
• Make sure that work area is uncluttered, and visitors are at a safe range from the tools and debris.
• Use a vise or clamping device to hold work piece firmly in place.
• Do not apply excessive force on tool or apply "rough" treatment to it.
• Always work with a firm footing, posture and proper lighting.
Report to your supervisor any condition of the tool, accessories, or operation you consider unsafe.
Regulator
Filter
• Ideally the air supply should be free from moisture.
Incorporating a refrigerated air dryer after the
compressor and drain valves at each tool station
(as shown) further reduces moisture from
condensation in the air supply.
OPERATING INSTRUCTIONS (continued)
Air System
Lubricator
90 PSIG
(6.2 Bar)
Closed Loop Pipe System
To Tool Station
Regulator
Filter
Lubricator
Ball
Valve
Drain
Valve
Drain
Valve
Air Tool
90 PSIG MAX
(6.2 Bar)
®
must be started at a reduced speed to check for good balance.
Air Flow
Ball
Valve
Air Hose
Air Flow
Air Compressor
and Receiver
Drain
Valve
• Dynabrade Air Power Tools are designed to
operate at 90 PSIG (6.2 Bar/620 kPa) maximum
air pressure at the tool inlet, when the tool is
running. Use recommended regulator to control
2
air pressure.
LUBRICATOR SETTING
1 DROP/MIN.
10 SCFM
Refrigerated
Air Dryer