SA220 (Sailor) Programming Method "A"
Procedure A
1. Remove the LHF kick panel to gain access to the Central Locking
controller.
2. Refer to the diagram below and earth out pin 9 three times (the door
locks will cycle during this process).
3. Press the Lock button on all remotes one at a time to lean the remotes.
4. Remove the earth wire and refit the module and trim.
NOTE:
The ignition key should not be in the ignition during this procedure.
(If you are unsuccessful try Earthing Pin 9, 5 times or attempt Procedure B on next page)
11