SA220 (Sailor) Programming Method "B"
Procedure B
1. Remove the LHF kick panel to gain access to the Central Locking controller.
2. Ensure all the doors are in an unlocked state.
3. Refer to the diagram below and earth out pin 9 of the controller.
4. Insert the ignition key into the ignition and turn the key from Off to On 4 to 6 times
within 25 seconds finishing on the ON position.
5. At this point the doors will lock and unlock once to indicate that the programming
mode has been entered.
6. Press the Lock button on all the remotes one at a time to lean the remotes. After
each press of the Lock button the doors will lock and unlock once to indicate that
the key has been learned.
7. Remove the earth wire and refit the module and trim.