8. Setting The Controller

Turn on the power and the softener will display Welcome
The display will automatically alternate between Time and Hardness.
To commission the water softener you will need to set both Time (24hr Clock in hours and
minutes) and Hardness as determined above.

Set Time of Day

Wait until the display reads Time.
Press the up arrow and the display
Will change to Set Time : 8:00*
Using the up and down arrows set to
the current time of day (24 Hr Clock)
while the figures flash.
*if the time has advanced don't worry
Just programme as normal.
Power indicator light
Down Arrow Button
Regeneration button
Up Arrow button

Set Water Hardness

Wait until the display changes to Hardness then press the up arrow and the display will change
to Set Hardn:10
Using the up and down arrows set the display to the number obtained in your hardness test.
That's it you've finished the programming. The display will now revert to the alternating display.
If at any time you need to re-programme or re-set any figure then just wait until the display
changes to the relevant setting and press the up arrow to get started.
9. Flush the Water Softener - IMPORTANT
Close the by-pass valve and open the inlet and outlet valves (fig 1) and Check for leaks.
Open a mains soft tap and allow this to run for at least 5 minutes. This will purge any air and
resin dust (which may appear brown or orange in colour) from the system.
Fill the softener with a good quality Tablet salt. To within 100mm of the top of the cabinet.
The water softener will not generally have water in the salt tank and is known as a dry salt
softener. When regenerating the softener will add water to the salt tank as required.
Part of this commissioning only, add 1 litre of water to the salt tank.
If at any time the softener has a significant amount of water in the salt tank and the softener is
not regenerating then please contact us for advice or a service visit.
Great Water: 01932 245783 [email protected]
5