Protection:
-Reverse polarity protected
-Inputs are electrostatic discharge protected
-Maximum power supply surge before damage: 1500V for 250us
Outputs:
-All outputs switched to +battery (sourcing)
-2 Auxilliary Outputs: User configurable to one of 6 different options through software.
Connections
-Removable terminal blocks for input and output connections
Programming
-Windows based software interface utilizing the parallel port of your PC
-Needs no power to program using the PC Interface – uses power from parallel port of PC