Automatic Technology Australia Elite Installationsanleitung und Benutzerhandbuch - Seite 13

Blättern Sie online oder laden Sie pdf Installationsanleitung und Benutzerhandbuch für Toröffner Automatic Technology Australia Elite herunter. Automatic Technology Australia Elite 20 Seiten. Swing gate opener with remote control

C O N T R O L L E R S M O D E S E L E C T I O N S W I T C H E S
This section describes the operating modes which can be se-
lected by the user using the control board's mode selection
switches [23] Fig 11.
SYNCHRONISED OVERLAPPING
GATE LEAFES.
1. When dual swing gates are used it is common for a back stop
to be mounted on one of the gate leaves so that the gate leaves
are aligned when closed. To prevent the gate leaves from inter-
fering with each other, the gate leaf with the back stop must
reach the close position first when closing and open last. The
controller can be made to do this by placing the mode selection
dip-switch labeled "SYNCHRONISING DELAY" into the
"ON" position. This will result in the gate leaf driven by motor
1 start to open 2 seconds before the gate leaf driven by motor 2
and the gate leaf driven by motor 2 start to close 2 seconds be-
fore that of motor 1. Note, if a lock is to be mounted on a gate
leaf, it should be mounted on the leaf driven by motor 1. If the
delay of 2 seconds is not suitable it can be altered, see sections
SYNCHRONISING DELAY TIME. on page 15.
AUTO-CLOSE MODES
The auto-close modes automatically close the gate after it has
been operated. To implement this, the controller starts a timer
once the gate has reached its desired open position. The timer
then counts down and when it expires the controller starts to
close the gate. The timer's count down can be suspended by ac-
tivating a suspending input (which inputs 'suspend' depends on
which auto-close mode is selected). When the input is deacti-
vated the auto-close timer is reloaded and the count down re-
commenced. The auto-close functions are temporarily disabled
by certain actions. When this happens the controller will not
auto-close the gate again until the user performs some action to
re-enable the function. Details about the three auto-close modes
follow.
2. STANDARD AUTO-CLOSE
This mode is selected by placing the mode selection switch la-
beled "STANDARD AUTO-CLS" into the "ON" position.
When selected the gate will auto-close 30 seconds after being
fully opened. The following gives details about this auto-close
mode.
Auto-closes after being:
• Fully opened. (except when the gate is reversed to the open
position after a motor overload is detected while closing)
Countdown suspended by:
• The P.E. input being active.
• The OPN input being active.
Function temporarily disabled by:
• Activating the STP input while the gate is open.
• A motor overload causing the gate to reverse open.
Function re-enabled by:
• Activating the OPN input while the gate is open.
• Activating the OSC input, in SWIPE mode, while the gate is
open.
•. By activating any input which cases the gate leaf to start to
close. The auto-close function will then be enabled once the
gate is re-opened.
The standard delay time of 30 seconds can be altered, see
STANDARD AUTO-CLOSE DELAY TIME, on page 15.
3. PEDESTRIAN ACCESS AUTO-CLOSE.
This mode is selected by placing the mode selection dip-switch
labelled "PEDESTRIAN AUTO-CLS" into the "ON" position.
When selected, the gate leaf will auto-close 15 seconds after be-
ing opened for pedestrian access.
Auto-closes after being:
• Driven to the programmed pedestrian access position. (Except
when the gate leaf is reversed after a motor overload is de-
tected.) Reversing during pedestrian access is only implemented
when special PED modes are selected.
• Stopped by the P.E. input when closing after pedestrian access
(standard PED mode only).
Countdown suspended by:
• The P.E. input being active.
• The PED input being active.
Function temporarily disabled by:
• Activating the STP input while the gate leaf is in the pro-
grammed pedestrian access position.
• Activating the STP input in condition 2 of 'Auto-closes after
being above.
• A motor overload causing the gate to reverse back to the pro-
grammed pedestrian access position. (Reversing during pedes-
trian access is only implemented when special PED modes are
selected.)
Function re-enabled by:
Activating the PED input, in SWIPE mode, while the gate is in
the programmed pedestrian access position. Activating the PED
input and causing the gate leaf to start to close.
The standard delay time of 15 seconds can be altered, see section
PEDESTRIAN ACCESS AUTO-CLOSE DELAY TIME on
page 15.
4. P.E TRIGGERED AUTO-CLOSE
This mode is selected by placing the mode selection dip-switch
labeled "P.E. TRIGGERED AUTO CLS" into the "ON" posi-
tion. When this auto-close mode is selected, the gate will auto-
close after the P.E. input has been activated and released since:
1. The gate was last closed
2. The P.E. triggered auto-close function was re-enabled after
being disabled.
3. The SWIPE input was activated.
Auto-closes after the P.E. input has been activated
and then released and the gate:
• Is fully opened. (except when the gate is reversed to the open
position after a motor overload is detected while closing)
• The gate has been stopped by the P.E. input.
Countdown suspended by:
• The P.E. input being active.
• The OPN input being active.
Function temporarily disabled by:
• Activating the STP input.
• A motor overload causing the gate to stop or reverse open.
Function re-enabled by:
• Activating the OPN input while the gate is open.
• Activating the SWIPE input.
• By activating any input which cases the gate to start to open or
close. The auto-close function will then be enabled once the gate
is re-opened or the P.E. input causes the gate to stop.
Page 13