Automatic Technology Australia Elite Installationsanleitung und Benutzerhandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Installationsanleitung und Benutzerhandbuch für Toröffner Automatic Technology Australia Elite herunter. Automatic Technology Australia Elite 20 Seiten. Swing gate opener with remote control

C O N T R O L L E R S M O D E S E L E C T I O N S W I T C H E S
If the P.E. input is configured to stop the gate during opening
or closing, then the gate can auto-close from a midway posi-
tion. This feature is implemented so that once a vehicle has en-
tered the gateway and broken the P.E. beam, the gate will stop.
When the P.E. beam is cleared the gate will auto-close from
the stopped position. This results in the gate not having to fully
open and thus reducing the time unwarranted access through
the gate is possible. The factory set delay time of 1 second is
adjustable, see section "P.E. TRIGGERED AUTO-CLOSE
DELAY TIME" below.
MIXING AUTO-CLOSE MODES.
The PEDESTRIAN AUTO-CLS mode and the STANDARD
AUTO-CLS mode do not affect each other as one operates dur-
ing standard operation and the other during pedestrian access.
However it is possible to have P.E. triggered pedestrian auto-
close by selecting both the PEDESTRIAN AUTO-CLS and
This section covers details on how to adjust several parameters
via the control boards buttons and dials (Fig 11).
Other adjustments can be performed by use of the advanced
technicians CB-9 V3.03 Control Board Instruction Manual
and Programmer. Contact your local ATA distributor for ser-
vice.
SYNCHRONISING DELAY TIME.
The synchronising delay time is adjusted using the 'SYNC de-
lay timer' button [34]. The synchronising delay time is adjust-
able in 0.1 second steps. The factory set default is 2 seconds.
STANDARD AUTO-CLOSE DELAY TIME.
The standard auto-close delay time is adjusted using the 'STD
auto-close' button [33]. The standard auto-close delay time is
adjustable in 1 second steps. The factory set default is 30 sec.
PEDESTRIAN ACCESS AUTO-CLOSE DELAY TIME.
The pedestrian auto-close delay time is adjusted using the 'PED
auto-close' button [32]. The pedestrian auto-close delay time is
adjustable in 1 second steps. The factory set default is 15 sec.
P.E. TRIGGERED AUTO-CLOSE DELAY TIME.
The P.E. triggered auto-close delay time is adjusted using the
'P.E. auto-close' button [31]. The P.E. triggered auto-close de-
lay time is adjustable in 1 second steps. The factory set default
is "off".
PEDESTRIAN ACCESS CYCLE TIME.
The pedestrian access cycle time sets how far gate leaf 1 opens
for pedestrian access.
1.Drive the gate to the closed position using the OSC button
[35] or another control input.
2.Press and hold the 'PED cycle timer' button [30]. The gate
leaf driven by motor 1 will start to open.
C O N T R O L B O A R D A D J U S T M E N T S
P.E. TRIGGERED AUTO-CLS modes. In this case the gate
would partly open for pedestrian access and then either the P.E.
TRIGGERED AUTO-CLS would cause the gate to auto-close
when a pedestrian walks through and activates the P.E beam or,
if no one walked through the PEDESTRIAN AUTO-CLS
would close the gate. This way the gate is only kept open long
enough for a person to walk through, but with the backup that
if no one walks through the gate will still close. The same con-
cept can be used with standard operation by selecting both the
STANDARD AUTO-CLS and the P.E. TRIGGERED AUTO-
CLS modes. That is, the gate would only stay open long
enough for the vehicle to pass through but would still auto-
close if no vehicle enters.
Note P.E. TRIGGERED AUTO-CLS will not operate during
pedestrian access unless the PEDESTRIAN AUTO-CLS mode
is also selected.
3.When the gate leaf has reached a position suitable for
pedestrian access, release the button.
4.The pedestrian access drive timer has now been set. Either
press the OSC button [35] and exit the time set mode or con-
tinue setting one of the synchronising delay or auto-close
times.
SLOW MOTOR SPEED.
IMPORTANT NOTICE: Please make sure that the gate(s)
are in the open position before proceeding with steps 1 to 5
below.
The speed the motor slows down towards the end of a cycle
can be adjusted using the following procedure. The factory set
default slow speed is set to " 3"
1.Note the current maximum speed selected by the speed
selection dial [24].
2.Using the speed selection dial [24] select the desired slow
speed.
3.Press and hold the 'RESET' button [29] and count five (5)
flashes of the OPEN status led [28].
4.Release the button.
5.Place the speed selection dial [24] back to the desired
maximum speed .
Adjustment method for auto-close and
times.
1.Press and hold the required button for the desired time.
2.Release the button.
3.Press the OSC button [35] to exit the time setting mode or
restart from step 1 to set another time.
Notes
a) The time setting mode is indicated by both the OPEN and
CLOSE status LED's being off.
b) Each flash of the OPN led represents 1 second.
c) When a button is first pressed, the CLOSE status led [27]
turns on. The time delay is set to zero when the CLOSE led
turns off and then increases for as long as the button is held.
Page 14
ynchronising delay
S