Aire WELKIN Anleitung Handbuch - Seite 13
Blättern Sie online oder laden Sie pdf Anleitung Handbuch für Fan Aire WELKIN herunter. Aire WELKIN 17 Seiten.
OPERATING THE REMOTE CONTROL / WALL CONTROL
Note: The auto learning function will only mandate within 60 seconds when
turning the fan's AC power ON.
1. Select desired frequency from the back of transmitter.
2. Press the transmitter's "Off" button, and hold the "Off" button for over 10
seconds. Once the receiver has detected the frequency, the down light of
your fan if applicable will blink twice. (There is no indication if your fan is not
equipped with a light).
Note: The learning frequency function will continue to retain the last set
frequency even when the AC power is shut off.
The DC motor has a built in safety feature against obstruction during operation,
if the fan motor senses a obstruction for 60 seconds or more it will get locked
and will not rotate until the obstruction has been removed and the power has
been disconnected for 5 seconds.
3. Over 60W protection: When the receiver detects motor power consumption
which is greater than 60W, the receiver's power will stop and operation will
be immediately discontinued. if you want to re-start the fan, Please remove
obstacles and disconnect the power by turning off the circuit breaker . And
turn the power on after 5 seconds.
4. "DIMMER" and "ON/OFF" dip switch:
The "DIMMER" selection is the light dimmable selection and is to be used
with all bulbs except for CFL bulbs. The"ON/OFF" selection is For CFL bulbs.
12
Fig. 18