Autonics PSQ-C01 Series Datenblatt - Seite 11
Blättern Sie online oder laden Sie pdf Datenblatt für Messgeräte Autonics PSQ-C01 Series herunter. Autonics PSQ-C01 Series 14 Seiten. Dual lcd display digital pressure sensor
Compact, Dual LCD Display Digital Pressure Sensor
Functions
Parameter copy
※
This function is for copying parameter settings of Master
to Slave 1:1. Master and Slave should be the same
specification model.
(brown) +V
[Master]
(blue) 0V
(black) OUT1 (black) OUT1
(white) OUT2
At Master unit,
Set parameter copy [COPY] of
PA 2 group as
At Master unit,
SV display part:
Turn OFF the Master unit
Connect Master/Slave units
Turn ON the Master/Slave units
with pressing the
[Master unit]
PV display: arbitrary value
SV display:
[Slave unit]
PV display: arbitrary value
SV display:
Turn OFF the Master/Salve units
and disconnect
Master/Slave units
※ 1: ON: Copies SVs.,
ON-L: Copies SVs and locks front keys of Slave unit.
※ 2: When connecting
Master unit and Slave unit incorrectly,
the PV display of Master unit displays
Turn OFF the Master unit power and turn ON it.
It displays REDY at SV display part.
※ 3: The PV display part of
Master displays as orange
color. The PV display part of Slave displays as green
color. When completing copy, the PV display part of
Master and Slave displays the same arbitrary value.
※ 4: Connect other Slave units to copy parameters.
Analog output scale adjustment
※
only for NPN or PNP open collector output+
analog output or external input type
Set output voltage, output current to the current display
value at 1-5VDC voltage output [A-V], DC4-20mA [A-C]
current output.
ᆞSet pressure value for 1VDC output [A-1V] and
pressure value for 5VDC output [A-5V].
[A-1V] setting range: 0% F.S.≤ [A-1V] ≤ 100% F.S.
[A-5V] setting range: 0% F.S.≤ [A-5V] ≤ [A-1V] -10% F.S. or
[A-1V]
ᆞSet pressure value for 4mA output [A-04] and
pressure value for 20mA output [A-20].
[A-04] setting range: 0% F.S.≤ [A-04] ≤100% F.S.
[A-20] setting range: 0% F.S.≤ [A-20]≤ [A-04]-10% F.S. or
[A-04]
[Slave]
(white) OUT2
※ 1
or
ON
ON-L
M
REDY
※ 4
※ 2
key
M
※ 3
COPY
OK
ERR4.
10% F.S.≤ [A-5V] ≤100% F.S.
+
10% F.S.≤ [A-20]≤100% F.S.
+
Auto Shift/Remote Zero/Hold input
※
Only for NPN or PNP open collector output+
analog output or external input type
Auto Shift [SHFT], Remote Zero [ZERO]
When reference pressure of the pressure sensor changes,
apply auto shift or remote zero digital input. It corrects
present pressure to reference pressure and by moving
detection level as much as fluctuation level. In case of
remote zero, it is the same function as auto shift but
remote zero makes the measured pressure as 0 forcibly.
When changing analog output and external input setting,
auto shift correction value [ShIN], remote zero correction
value [ZeIN] are also reset as 0.
ᆞSetting correction value
: Press the
,
key to set SV manually or
to orange cable over 1ms.
When selecting analog output/external input
parameter 1 group as
[SHFT] or [ZERO], press the
key to select control output
correction value.
ᆞDeleting correction value
Press the
keys for over 1 sec to delete
+
:
shift correction.
Hold [HOLD]
The function to hold PV and control output while signal is input.
Output mode change
OUT1 operation mode
There are 4 kinds of control output mode in order to realize
the various pressure detection.
• Hysteresis mode [HYsM]
: When needed to change hysteresis for detecting pressure.
• Window comparison output mode [WIN]
: When needed to detect pressure in certain area.
• Automatic sensitivity setting mode [AUTO]
: When needed to set detection sensitivity automatically at
proper position.
• Forced output control mode [fOUT]
: When needed to display pressure with remaining
comparison output OFF regardless of setting value.
OUT2 operation mode
Select control output mode between two types or OFF.
In case of OUT1 operation mode, select automatic sensi-
tivity setting mode [AUTO] or forced output control mode
[fOUT]. OUT2 operation mode setting is inactive.
• Hysteresis mode [HYsM]
: When needed to change hysteresis for detecting pressure.
• Window comparison output mode [WIN]
: When needed to detect pressure in certain area.
• OFF [OFF]
apply
0VDC
[I/O] of
M
at
[ShOT], [ZeOT] to be with
set
auto
G-19
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(A)
Photoelectric
Sensors
(B)
Fiber Optic
Sensors
(C)
LiDAR
(D)
Door/Area
Sensors
(E)
Vision
Sensors
(F)
Proximity
Sensors
(G)
Pressure
Sensors
(H)
Rotary
Encoders
(I)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets