PSQ Series

Parameter Setting

※ After entering parameter 1/2 group, if there is no additional key input for 60 sec, it maintains previous setting value and it returns to RUN mode.
※ Press the
,
key to set the setting value.
※ After entering parameter 1/2 group, press the
※ When pressing the
key once returning RUN mode from parameter 1 group, 2 group within 2 sec, it enters the previous parameter group.
M
※ Some parameters are activated/deactivated according to the setting of other parameters. Refer to the description of each parameter.

Parameter Group

Parameter 1 group
Parameter name
Setting range
OUT1 operation
OUT1
mode
OUT2 operation
OUT2
mode
Analog output/
※ 1
I/O
External input
Auto shift
※ 1
ShOT
applied terminal
Remote zero
※ 1
ZeOT
applied terminal
NoNC Output type
SPD Response time
PV display color
CLOR
Color linked
DISP
output
UNIT Display unit
※ 1: Appears only in NPN or PNP open collector output + analog output or external input model.
G-14
key for over 2 sec to return to RUN mode.
M
Easy
EASY
Hysteresis
HYsM
Window comparison
WIN
Auto sensitivity setting
AUTO
Forced output control
fOUT
OFF
OFF
Easy
EASY
Hysteresis
HYsM
Window comparison
WIN
Analog voltage output
A-V
Analog current output
A-C
Auto shift
SHFT
Remote zero
ZERO
Hold
HOLD
OUT1
OUT1
OUT2
OUT2
OUT1 & OUT2
ALL
OUT1
OUT1
OUT2
OUT2
OUT1 & OUT2
ALL
OUT1
OUT2
NO Normally Open
OFF
NC Normally Closed
OFF
1O2O Normally Open
Normally Open
1O2C Normally Closed
Normally Open
1C2O Normally Closed
Normally Open
1C2C Normally Closed
Normally Closed
@5, 5,10, 25, 50, 100, 250,
500, 1000, 5000
Normal: Green / Output: Red
R-ON
Normal: Red / Output: Green
G-ON
Fixed red
RED
Fixed green
GREN
OUT1
OUT1
OUT2
OUT2
OUT1 & OUT2
ALL
kPa
KPA
MPa
MPA
2
kgf/cm
KGF
bar
BAR
psi
PSI
mmHg
MMHG
inHg
INHG
mmH
O
H2O
2
Description
Select OUT1 operation mode.
※ When setting OUT1 operation mode as auto sensitivity setting mode [AUTO] or
forced output control mode [fOUT], OUT2 operation mode is set automatically
same as the setting value of OUT1 operation mode.
Select OUT2 operation mode.
Select analog output/external input operation mode.
Auto shift:
When reference pressure of the pressure sensor changes, It
corrects present pressure to reference pressure and by moving
detection level as much as fluctuation level.
Remote zero:
It is the same function as auto shift but remote zero
makes the measured pressure as 0 forcibly.
Hold: The function to hold present value (PV) and control output while
signal is input.
※ When OUT1 operation mode is set as [fOUT] or applied pressure
is higher/lower than the display pressure range, auto shift [SHFT],
remote zero [ZERO] functions are not available.
Select auto shift applied terminal.
※ Appears when Analog output/External input is [SHFT].
Select remote zero applied terminal.
※ Appears when analog output/external input is [ZERO].
※ Appears when OUT2 operation mode is [OFF].
※ Appears when OUT1 operation mode is [AUTO],
or OUT2 operation mode is [HYsM], [WIN].
It can prevent control output from chattering by changing response time.
※ If the response time is getting longer, the detection will be more stable
but present value (PV) might be different from the real pressure
value.
Select the present value (PV) display and the color linked output.
Select the color linked output.
※ Appears when OUT2 operation mode is not [OFF] and PV display color
is set as [R-ON] and [G-ON].
Select the display unit.
For using mmH
O unit, multiply display value by 100.
2
Factory
default
EASY
OFF
A-V
OUT1
OUT1
NO
@5
R-ON
OUT1
KPA