caused.
4) No Volt Output:
No generator volt output is detected. Check the generator
connection cable and the belt whether they are normal.
5) Diode Test:
Through the test of charging current ripple, tester will find out
whether the diode is normal or not. When ripple volt is too high, it
proves at least one diode is damaged. Check and replace the diode.
Till now, all tests have been done.
4. Daily Maintenance

4.1 Eliminate Common Fault

4.1.1 Screen Not Light

Check connection with the battery whether it's well or reverse
connected.
Check the test cable whether break off or drop down.
5. Warranty Service
There are 3 years' warranty for AUTOOL product main unit and 1 y
ear warranty for the accessories since the day customers have rec
eived the product parcel.
Warranty Access
1. Repair or replace the equipment will be done according to the specific fault
conditions;