Galletti FM 33 Technisches Handbuch - Seite 15
Blättern Sie online oder laden Sie pdf Technisches Handbuch für Klimagerät Galletti FM 33 herunter. Galletti FM 33 20 Seiten. High wall-mounted fan coil units with bldc motor and incorporated valve 2.0 kw-3.7 kw
FM
10
INSTALLATION REqUIREMENTS
Clearance for maintenance and repairing is shown above
** All dimensions are in mm.
The signal receiver on the unit must be kept as far away as possible from
any source of high frequency emissions.
Keep the unit away from fluorescent lamps which can affect the control
system.
To avoid electric or magnetic interference of the control system, make sure
that the control cables are installed separately from 220-240 Vac electric
cables.
Where electromagnetic waves are present, use shielded cables for the
sensors.
Install a filter if harmful interferences are present in the power supply.
Filter
FC66003740 - Rev 01
11
ROUTINE MAINTENANCE
The material must undergo maintenance in order to retain its characteristics
over time. Lack of maintenance may have the effect of voiding the product
warranty.
We recommend cleaning it once a month, but the frequency depends on
operating conditions.
To remove the filter Open the grill by lifting it from the lower position
indicated by the arrow.
Remove the filter from the grille.
Use a vacuum cleaner to remove dust. If dust is glued to the filter, remove it
with clean or soapy water, rinse the filter with clean water and dry it.
Put the filter back into its housing in the grill.
Close the liftable grill by pressing both sides down, into the position
indicated by the arrow.
All copying, even partial, of this manual is strictly forbidden
15