Galvin Engineering WaterMark 46664 Installations-Manuale - Seite 3
Blättern Sie online oder laden Sie pdf Installations-Manuale für Sanitärprodukt Galvin Engineering WaterMark 46664 herunter. Galvin Engineering WaterMark 46664 4 Seiten. Bs lever action sba
Product Installation Guidelines
TROUBLESHOOTING
PROBLEM
Taps are dripping water
Water is leaking from spindle
Water is not flowing from tap
Spindle is difficult to turn
Handle is loose
© Galvin Engineering Pty Ltd
CAUSE
Jumper valves are worn or damaged
Ceramic discs are worn or damaged
Tap seat is damaged
O-ring on jumper valve spindle is
damaged or worn
Water is turned off
Ceramic discs are worn or damaged
Ceramic discs are worn or damaged
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Screw has come loose
Document Number: 001.00.70.13
Version 1, 4 November 2022, Page 3 of 4
RECTIFICATION
Replace jumper valve
Remove and inspect SBA. Remove
debris and/or replace SBA if
damaged.
Refurbish tap seat using a reseating
tool.
Replace o-ring
Turn on water
Remove and inspect SBA. Remove
debris and/or replace SBA if
damaged.
Remove and inspect SBA. Remove
debris and/or replace SBA if
damaged.
Remove jumper valve, clean and
regrease. Replace o-ring. Complete
SBA may need to be replaced.
Tighten handle screw