IDEAA SPLITTER MODULE INSTALLATION
MOUNT IDEAA SPLITTER MODULE
1. Using local engineering practices, determine the
location of the IDEAA Splitter Module to be installed
within the IDC.
2. Using the provided hex-head screws, attach the
mounting bracket to the bottom side of the IDEAA
Splitter Module. (Figure 14)
3. Install the IDEAA LGX-118 Rack Mount Bracket into
the LGX-118 mounting fixture by pressing in the two
nylatch plungers. (Figure 16)
4. Repeat Steps 1 – 3 for each IDEAA Splitter Module
to be mounted.
ACTIVATE IDEAA SPLITTER MODULE
An IDEAA Splitter Module that has been mounted into
the IDC is not active until it has been connected to the
Input Field.
Caution: When working with fiber optics, do
not look directly into the end of the fiber cable
or adapter port. A power meter may be used to
determine if the cable or port is dark. Or use
locally accepted fiber optic safety practices.
1. Use local accepted practices to clean the connector
end face at both ends of the jumper provided with the
IDEAA Splitter Module.
2. Plug the jumper cable into the black input port on
the IDEAA Splitter Module. Use the foam fiber relief
to route the jumper cable to the fiber routing section
of the IDC. (Figure 16)
Note: When mounted on the LGX-118 mounting
fixture the black input port will be located in the
bottom right corner of the module adapter field.
INSTALLATION INSTRUCTIONS
IDEAA
9
Interior Distribution Cabinet
®
Figure 14
Figure 15
Figure 16
© 2016, AFL, all rights reserved. Revision C, 3.3.17
Specifications are subject to change without notice.
Nylatch Plunger
Nylatch Plunger