MAINLINE ML100W Montageanleitung Pflege und Wartung - Seite 3

Blättern Sie online oder laden Sie pdf Montageanleitung Pflege und Wartung für Toiletten MAINLINE ML100W herunter. MAINLINE ML100W 11 Seiten. Round front toilet

Round Front Toilet
Devant de cuvette rond
Installation Instructions, Care and Maintenance
10
Adjustments
a. Adjust water level. Water level should be adjusted to level
indicated on tank by adjusting the float cup. See Step 11 for water
level adjustment method.
b. If bowl fails to siphon, an adjustment may be required with the lift
chain. Simply remove the bead chain from the retainer clip, take up
slack on the chain and re-insert on lift rod. Make sure the chain is not
too taut.
13

Troubleshooting

DIAGRAM 1: IMPORTANT:
Always clear sand and rust from system.
Make sure water supply is off. Remove
valve TOP by lifting arm and rotating top
and arm 1/8 turn counter- clockwise,
pressing down slightly on cap.
DIAGRAM 3: Replace TOP by engaging
lugs and rotating 1/8 turn clockwise.
MAKE CERTAIN TIP IS TURNED TO THE
LOCKED POSITION VALVE MAY NOT
TURN ON IF TOP IS NOT FULLY TURNED
TO THE LOCKED POSITION.
IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW
(After valve has been in use for some time).
Fluidmaster Replacement Seal may be needed.
VITREOUS CHINA
11
Adjust Water Level
a. Turn on water supply. Submerge the
FLOAT CUP under the water for 30
seconds. Adjust the water to desired
level by turning WATER LEVEL
ADJUSTMENT ROD and moving FLOAT
CUP up or down.
b. Once water level is correct with marking in tank, flush toilet 3 times
to prime toilet and "No Overflow" system. After prime has been
established toilet traps are self-priming from this point on. No further
priming is required. Use toilet for normal use.
12
Care and Cleaning
When cleaning your toilet, wash it with mild soapy water, rinse
thoroughly with clear water and dry with a soft cloth. Avoid detergents,
disinfectants, or cleaning products in aerosol cans. NEVER use abrasive
scouring powders or abrasive pads on your toilet seat. Some bathroom
chemicals and cosmetics may damage the seat's finish.
WARNING:
Do not use in-tank cleaners. Products containing chlorine (calcium
hypochlorite) can seriously damage fittings in the tank. This damage can
cause leakage and property damage. Mainline shall not be
responsible or liable for any tank fitting damage caused by the use of
cleaners containing chlorine (calcium hypochlorite).
DIAGRAM 2: While holding a container over
the uncapped VALVE to prevent splashing,
turn water supply on and off a few times.
Leave water supply off.
IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK SLOWLY:
Repeat Step 13.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON-USE:
It is a signal you are wasting water because:
a. The end of the refill tube is not inserted into overflow pipe, below
water level in tank. Attach refill tube to overflow pipe.
b. The flush valve is leaking because it's worn, dirty or misaligne
flapper (replace with a new flapper).